A new approach to detection of incomplete antibodies using hydrogel chromatography medium.
Wang, HongMei; Chen, YeZhou; Ding, ShaoHua; Duan, ShengBao; Tian, JingJing; Meng, QingLin; Wei, ShuangShi; Li, Yong.
Afiliação
  • Wang H; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China. Electronic address: wanghm449@aliyun.com.
  • Chen Y; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
  • Ding S; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
  • Duan S; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
  • Tian J; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
  • Meng Q; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
  • Wei S; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
  • Li Y; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China.
Transfus Apher Sci ; 53(3): 337-41, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26099667
In assays for incomplete antibody detection, several washing steps are required to remove unbound globulins which may cause false negatives. Here, we present an improved approach employing hydrogel chromatography medium (HCM) in the detection of incomplete antibodies. After a rapid single-step centrifugation, incomplete antibodies, attached to red blood cells (RBCs), were separated from the reaction mixture using HCM and sedimentation. This method obviates the need for multiple centrifugation steps found in conventional Tube-Coombs tests. The HCM-Coombs tests may have a wide range of applications for incomplete antibody detection.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hidrogéis / Anticorpos Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male Idioma: En Revista: Transfus Apher Sci Assunto da revista: HEMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article