Your browser doesn't support javascript.
loading
Randomised controlled trial comparing the Ambu® aScope™2 with a conventional fibreoptic bronchoscope in orotracheal intubation of anaesthetised adult patients.
Chan, J K; Ng, I; Ang, J P; Koh, S M; Lee, K; Mezzavia, P; Morris, J; Loh, F; Segal, R.
Afiliação
  • Chan JK; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Northern Hospital, Epping, Victoria.
  • Ng I; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Ang JP; Provisional Anaesthesia Fellow, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Koh SM; Provisional Anaesthesia Fellow, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Lee K; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Mezzavia P; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Morris J; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Loh F; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
  • Segal R; Consultant Anaesthetist, Department of Anaesthesia and Perioperative Medicine, Royal Melbourne Hospital, Parkville, Victoria.
Anaesth Intensive Care ; 43(4): 479-84, 2015 Jul.
Article em En | MEDLINE | ID: mdl-26099760
Fibreoptic intubation remains an essential skill for anaesthetists to master. In addition to the reusable fibrescope, an alternative disposable videoscope is available (aScope(™)2, Ambu®, Ballerup, Denmark). A total of 60 anaesthetised adult patients were randomised to either having orotracheal intubation using the aScope 2 or a Karl Storz fibrescope. Intubations were performed by experienced operators who were familiar with both devices. The primary outcome was the Global Rating Scale score. Secondary outcomes included intubation success, number of intubation attempts and intubation time. Other subjective outcomes including practicality, useability and image quality were also recorded. There was no significant difference in the Global Rating Scale score, intubation success orintubation time between the aScope 2 or Karl Storz fibrescope. Global Rating Scale scores were three and two in the aScope 2 and Karl Storz groups respectively (P=0.14). All of the other subjective outcomes were similar between the two groups, except that operators found it easier to use the aScope 2 compared to the fibrescope. There was no significant difference in clinical performance between the aScope 2 and the Karl Storz fibreoptic bronchoscope. The aScope's practicality, disposability and recently improved version (aScope(™)3) potentially make it an acceptable alternative to the reusable fibrescope.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Broncoscopia / Broncoscópios / Tecnologia de Fibra Óptica / Intubação Intratraqueal Tipo de estudo: Clinical_trials Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Anaesth Intensive Care Ano de publicação: 2015 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Broncoscopia / Broncoscópios / Tecnologia de Fibra Óptica / Intubação Intratraqueal Tipo de estudo: Clinical_trials Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Anaesth Intensive Care Ano de publicação: 2015 Tipo de documento: Article