Your browser doesn't support javascript.
loading
99mTc-MDM Brain SPECT for the Detection of Recurrent/Remnant Glioma-Comparison With ceMRI and 18F-FLT PET Imaging: Initial Results.
Singh, Baljinder; Kumar, Narendra; Sharma, Sarika; Watts, Ankit; Hazari, Puja P; Rani, Nisha; Vyas, Sameer; Anish, Bhattacharya; Mishra, Anil K.
Afiliação
  • Singh B; From the *Nuclear Medicine & PET, PGIMER, Chandigarh, India; †Radiation Oncology, PGIMER, Chandigarh, India; ‡Division of Radiopharmacy and PET/Cyclotron Centre, INMAS, DRDO, Delhi, India; and §Department of Radiodiagnosis, PGIMER, Chandigarh, India.
Clin Nucl Med ; 40(10): e475-9, 2015 Oct.
Article em En | MEDLINE | ID: mdl-26204205
PURPOSE: To evaluate the diagnostic use of an indigenously developed single vial ready to label (with Tc) kit preparation of bis-methionine-DTPA (Tc-MDM) for the detection of recurrent/residual glioma. MATERIALS AND METHODS: We prospectively studied 32 patients (21 male and 11 female subjects aged 43.0±16.0 years) with clinical suspicion of postoperative recurrent/residual glioma. After radical radiotherapy (54.0-60.0 Gy) with or without concurrent temozolomide as indicated, Tc-MDM SPECT and ceMRI of the brain was performed in all the patients and F-FLT-PET imaging in 16 of 32 patients. RESULTS: MDM SPECT and ceMRI findings were concordant in 28 patients (15 positive and 13 negative). The findings were discordant in the remaining 5 patients, with positive ceMRI and negative MDM-SPECT in 2 patients and negative ceMRI and positive MDM-SPECT in 3 patients. Tc-MDM-SPECT, F-FLT PET, and ceMRI scan findings were positive in 9 of 16 and negative in 5 of 16 patients. In the remaining 2 of 16 patients, both F-FLT-PET and Tc-MDM-SPECT were positive, but ceMRI was negative. Sensitivity, specificity, PPV, NPV, and DA of Tc-MDM-SPECT for diagnosing recurrent/residual glioma were 88.24%, 81.25%, 83.3%, 86.7%, and 84.8%, respectively. CONCLUSIONS: The diagnostic accuracy of Tc-bis-methionine (MDM)-SPECT imaging was comparable with that of ceMRI and F-FLT-PET and may be useful in the management of glioma patients in the postsurgical follow-up period. This imaging technique may be of special interest in peripheral hospitals/developing countries lacking access to expensive PET/cyclotron technology. However, comparison with the existing "gold standard" PET tracers, especially with C-11-methionine-PET imaging and histopathological correlation, is warranted in a large cohort of glioma patients through multicentric studies.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Didesoxinucleosídeos / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Compostos Radiofarmacêuticos / Ácido Pentético / Glioma Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Nucl Med Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Didesoxinucleosídeos / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Compostos Radiofarmacêuticos / Ácido Pentético / Glioma Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Nucl Med Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Índia