Your browser doesn't support javascript.
loading
Does the disparity in baseline characteristics of patients undergoing transcatheter aortic valve replacement with 23 mm vs. 26 mm valves impact clinical outcome?
Escárcega, Ricardo O; Magalhaes, Marco A; Baker, Nevin C; Lipinski, Michael J; Minha, Sa'ar; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron.
Afiliação
  • Escárcega RO; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Magalhaes MA; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Baker NC; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Lipinski MJ; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Minha S; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Torguson R; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Chen F; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Satler LF; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Pichard AD; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
  • Waksman R; Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC.
Catheter Cardiovasc Interv ; 87(1): 176-82, 2016 Jan 01.
Article em En | MEDLINE | ID: mdl-26257081
OBJECTIVES: We sought to identify if baseline characteristic differences in patients who receive a 23 mm vs. 26 mm valve impact clinical outcomes. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is currently an approved therapy for patients with severe aortic stenosis who are considered inoperable or are at high risk. METHODS: We retrospectively examined baseline characteristics and outcomes of patients receiving a 23 mm (n = 132) vs. 26 mm valve (n = 81) via the transfemoral approach. RESULTS: Gender (P < 0.01), previous coronary artery bypass surgery (P < 0.01), history of atrial fibrillation (P = 0.04), and mean Society of Thoracic Surgeons (STS) score (P < 0.01) were significantly different between groups. There were no significant differences in the rates of minor/major vascular complications (2.2 vs. 3.7%, P = 0.68 and 13.0 vs. 12.3%, P = 0.89, respectively). Bleeding complications were also comparable (major bleed 2.3 vs. 1%, P >0.99, minor bleed 19.0 vs. 22.0%, P = 0.67 and life threatening bleed 7.0 vs. 5.0%, P = 0.77). In-hospital death (6.0 vs. 5.0%, P >0.99), 30-day all-cause death (7.6 vs. 6.2%, P = 0.69), and all-cause death at 1 year (17.4 vs. 25.9%, P = 0.13) were also similar between groups. Gender, valve size, previous coronary bypass surgery and atrial fibrillation were not independently associated with mortality; however, on multivariate analysis STS score was (HR 1.11; 95% CI 1.02-1.19; P = 0.01). CONCLUSION: Patients undergoing TAVR with 23 and 26 mm valves have similar clinical outcomes despite significant differences in baseline characteristics. © 2015 Wiley Periodicals, Inc.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2016 Tipo de documento: Article