Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry.
Moscarella, Elisabetta; Varricchio, Attilio; Stabile, Eugenio; Franzone, Anna; Granata, Francesco; Rapacciuolo, Antonio; Galasso, Gennaro; Capozzolo, Claudia; Cirillo, Plinio; Monda, Vittorio; Monterforte, Ida; Borgia, Francesco; Piro, Orlando; Bonzani, Giulio; Trimarco, Bruno; Esposito, Giovanni.
Afiliação
  • Moscarella E; Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi.
  • Varricchio A; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli "Federico II", Napoli, Italia.
  • Stabile E; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia. Electronic address: geko50@hotmail.com.
  • Franzone A; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
  • Granata F; Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi.
  • Rapacciuolo A; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
  • Galasso G; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
  • Capozzolo C; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli "Federico II", Napoli, Italia.
  • Cirillo P; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
  • Monda V; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli "Federico II", Napoli, Italia.
  • Monterforte I; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli "Federico II", Napoli, Italia.
  • Borgia F; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
  • Piro O; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli "Federico II", Napoli, Italia.
  • Bonzani G; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli "Federico II", Napoli, Italia.
  • Trimarco B; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
  • Esposito G; Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero "Monaldi", Azienda Ospedaliera "Dei Colli", Napoli, Italia.
Cardiovasc Revasc Med ; 16(7): 401-5, 2015.
Article em En | MEDLINE | ID: mdl-26342404
ABSTRACT
BACKGROUND/

PURPOSE:

Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. METHODS/MATERIALS Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months.

RESULTS:

A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6±15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%).

CONCLUSIONS:

Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fármacos Cardiovasculares / Stents / Materiais Revestidos Biocompatíveis / Implantes Absorvíveis / Reestenose Coronária / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Cardiovasc Revasc Med Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fármacos Cardiovasculares / Stents / Materiais Revestidos Biocompatíveis / Implantes Absorvíveis / Reestenose Coronária / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Cardiovasc Revasc Med Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2015 Tipo de documento: Article