Your browser doesn't support javascript.
loading
Sutureless 3F Enable Valve Replacement for Pure Aortic Regurgitation.
Vola, Marco; Fuzellier, Jean-François; Anselmi, Amedeo; Campisi, Salvatore; Haber, Benjamain; Isaaz, Karl; Gerbay, Antoine; Ruggieri, Vito Giovanni.
Afiliação
  • Vola M; Cardiovascular Surgery Unit, St-Etienne University Hospital, St-Etienne, France.
  • Fuzellier JF; Cardiovascular Surgery Unit, St-Etienne University Hospital, St-Etienne, France.
  • Anselmi A; Cardiovascular Surgery Unit, St-Etienne University Hospital, St-Etienne, France.
  • Campisi S; Cardiovascular Surgery Unit, St-Etienne University Hospital, St-Etienne, France.
  • Haber B; Cardiology Unit, St-Etienne University Hospital, St-Etienne, France.
  • Isaaz K; Cardiology Unit, St-Etienne University Hospital, St-Etienne, France.
  • Gerbay A; Cardiology Unit, St-Etienne University Hospital, St-Etienne, France.
  • Ruggieri VG; Cardiovascular Surgery Unit, St-Etienne University Hospital, St-Etienne, France.
J Card Surg ; 30(11): 796-800, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26434746
BACKGROUND AND AIM: We present our experience in the use of the sutureless valve in patients undergoing aortic valve replacement for pure aortic regurgitation. METHODS: Out of 167 patients who underwent sutureless aortic valve implantation with a Medtronic 3f Enable prosthesis in our unit between March 2011 and February 2014, 12 (7.1%) received a sutureless valve for pure aortic regurgitation. RESULTS: Mean age, logistic EuroSCORE, and left ventricular ejection fraction were 72 ± 5 years, 6.3 ± 2.9%, and 52.5 ± 15.3%, respectively. The sutureless valve could be successfully implanted in all cases; nine patients had a full sternotomy (associated coronary artery bypass graft in four cases and associated mitral surgery in five), one patient had a ministernotomy, and two had a thoracoscopic approach. Average cross-clamping and cardiopulmonary bypass times were 90 ± 30 and 127 ± 51 minutes, respectively. At the outpatient echocardiography, average mean gradient was 10.54 ± 4.99 mmHg and a grade I-II paravalvular leakage (PVL) was detected in the first patient of the cohort (ministernotomy approach). At a mean follow-up of 11.1 ± 5.5 months, average mean gradient was 9.75 ± 2.87 mmHg, no new PVL was detected, and the known PVL was stable. No pacemaker implantation was required. CONCLUSIONS: Implantation of the 3f Enable sutureless valve is technically possible with pure aortic regurgitation in selected patients. Multicenter investigations are necessary to assess the mid-term benefits of such a device in this subset of patients.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Insuficiência da Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Card Surg Assunto da revista: CARDIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Insuficiência da Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Card Surg Assunto da revista: CARDIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França