Your browser doesn't support javascript.
loading
Lack of concordance amongst measurements of individual anaerobic threshold and maximal lactate steady state on a cycle ergometer.
Arratibel-Imaz, Iñaki; Calleja-González, Julio; Emparanza, Jose Ignacio; Terrados, Nicolas; Mjaanes, Jeffrey M; Ostojic, Sergej M.
Afiliação
  • Arratibel-Imaz I; a Department of Physical Education and Sport , Faculty of Sport Sciences, University of Basque Country , Vitoria-Gasteiz , Spain.
  • Calleja-González J; a Department of Physical Education and Sport , Faculty of Sport Sciences, University of Basque Country , Vitoria-Gasteiz , Spain.
  • Emparanza JI; b Epidemiology and Public Health, CIBER-ESP, IIS BioDonostia , University Hospital Donostia , Donostia , Spain.
  • Terrados N; c Sports Medicine Regional Unit of Asturias-FDM Aviles and Department of Functional Biology , University of Oviedo , Oviedo , Spain.
  • Mjaanes JM; d Regional Department of Orthopedic Surgery and Pediatrics, Midwest Orthopedics at Rush , Rush University Medical Center , Chicago , IL , USA.
  • Ostojic SM; e Faculty of Sport and Physical Education , University of Novi Sad , Novi Sad , Serbia.
Phys Sportsmed ; 44(1): 34-45, 2016.
Article em En | MEDLINE | ID: mdl-26578151
ABSTRACT

INTRODUCTION:

The calculation of exertion intensity, in which a change is produced in the metabolic processes which provide the energy to maintain physical work, has been defined as the anaerobic threshold (AT). The direct calculation of maximal lactate steady state (MLSS) would require exertion intensities over a long period of time and with sufficient rest periods which would prove significantly difficult for daily practice. Many protocols have been used for the indirect calculation of MLSS.

OBJECTIVES:

The aim of this study is to determine if the results of measurements with 12 different AT calculation methods and calculation software [Keul, Simon, Stegmann, Bunc, Dickhuth (TKM and WLa), Dmax, Freiburg, Geiger-Hille, Log-Log, Lactate Minimum] can be used interchangeably, including the method of the fixed threshold of Mader/OBLA's 4 mmol/l and then to compare them with the direct measurement of MLSS.

METHODS:

There were two parts to this research. Phase 1 results from 162 exertion tests chosen at random from the 1560 tests. Phase 2 sixteen athletes (n = 16) carried out different tests on five consecutive days.

RESULTS:

There was very high concordance among all the methods [intraclass correlation coefficient (ICC) > 0.90], except Log-Log in relation to the Stegamnn, Dmax, Dickhuth-WLa and Geiger-Hille. The Dickhuth-TKM showed a high tendency towards concordance, with Dmax (2.2 W) and Dickhuth-WLa (0.1 W). The Dickhuth-TKM method presented a high tendency to concordance with Dickhuth-WLa (0.5 W), Freiburg (7.4 W), MLSS (2.0 W), Bunc (8.9 W), Dmax (0.1 W). The calculation of MLSS power showed a high tendency to concordance, with Dickhuth-TKM (2 W), Dmax (2.1 W), Dickhuth-WLa (1.5 W).

CONCLUSION:

The fixed threshold of 4 mmol/l or OBLA produces slightly different and higher results than those obtained with all the methods analyzed, including MLSS, meaning an overestimation of power in the individual anaerobic threshold. The Dickhuth-TKM, Dmax and Dickhuth-WLa methods defined a high concordance on a cycle ergometer. Dickhuth-TKM, Dmax, Dickhuth-WLa described a high concordance with the power calculated to know the MLSS.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Limiar Anaeróbio / Exercício Físico / Ácido Láctico / Teste de Esforço Tipo de estudo: Guideline / Observational_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Phys Sportsmed Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Limiar Anaeróbio / Exercício Físico / Ácido Láctico / Teste de Esforço Tipo de estudo: Guideline / Observational_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Phys Sportsmed Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Espanha