Theoretical and experimental studies for high-repetition-rate disordered crystal lasers with harmonic self-mode locking.
Opt Express ; 24(4): 3832-8, 2016 Feb 22.
Article em En | MEDLINE | ID: mdl-26907036
ABSTRACT
A harmonically self-mode-locked NdSr3Y2/(BO3)4 disordered crystal laser with subpicosecond pulse duration is demonstrated. We exploit the damped harmonic oscillator model to numerically verify that the mode spacing of the laser cavity can be modified to be the harmonics of the free spectral range of the Fabry-Perot cavity when the optical length of the laser cavity is close to a commensurate ratio of the optical length of the Fabry-Perot cavity. In experiment, the Fabry-Perot cavity can be formed by the pump facet of the disordered crystal and the front mirror. A 110 GHz single-pulse harmonically mode-locked pulse train with pulse duration of 857 fs is experimentally achieved under optical lengths of 27.19 and 4.08 mm for the laser cavity and Fabry-Perot cavity respectively, corresponding to a fractional number of 20/3. A maximum output power of 162 mW is obtained at an incident pump power of 3.1 W.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Opt Express Assunto da revista: OFTALMOLOGIA Ano de publicação: 2016 Tipo de documento: Article