Your browser doesn't support javascript.
loading
In Situ Ptychography of Heterogeneous Catalysts using Hard X-Rays: High Resolution Imaging at Ambient Pressure and Elevated Temperature.
Baier, Sina; Damsgaard, Christian D; Scholz, Maria; Benzi, Federico; Rochet, Amélie; Hoppe, Robert; Scherer, Torsten; Shi, Junjie; Wittstock, Arne; Weinhausen, Britta; Wagner, Jakob B; Schroer, Christian G; Grunwaldt, Jan-Dierk.
Afiliação
  • Baier S; 1Institute for Chemical Technology and Polymer Chemistry,Karlsruhe Institute of Technology,76131 Karlsruhe,Germany.
  • Damsgaard CD; 2Center for Electron Nanoscopy,Technical University of Denmark,2800 Kgs. Lyngby,Denmark.
  • Scholz M; 4Deutsches Elektronen-Synchrotron DESY,Notkestr. 85,22607 Hamburg,Germany.
  • Benzi F; 1Institute for Chemical Technology and Polymer Chemistry,Karlsruhe Institute of Technology,76131 Karlsruhe,Germany.
  • Rochet A; 1Institute for Chemical Technology and Polymer Chemistry,Karlsruhe Institute of Technology,76131 Karlsruhe,Germany.
  • Hoppe R; 5Institute of Structural Physics,Technische Universität Dresden,01062 Dresden,Germany.
  • Scherer T; 6Institute of Nanotechnology,Karlsruhe Institute of Technology,76021 Karlsruhe,Germany.
  • Shi J; 8Angewandte und Physikalische Chemie,University of Bremen,28359 Bremen,Germany.
  • Wittstock A; 8Angewandte und Physikalische Chemie,University of Bremen,28359 Bremen,Germany.
  • Weinhausen B; 9European Synchrotron Radiation Facility,38043 Grenoble,France.
  • Wagner JB; 2Center for Electron Nanoscopy,Technical University of Denmark,2800 Kgs. Lyngby,Denmark.
  • Schroer CG; 4Deutsches Elektronen-Synchrotron DESY,Notkestr. 85,22607 Hamburg,Germany.
  • Grunwaldt JD; 1Institute for Chemical Technology and Polymer Chemistry,Karlsruhe Institute of Technology,76131 Karlsruhe,Germany.
Microsc Microanal ; 22(1): 178-88, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26914998
ABSTRACT
A new closed cell is presented for in situ X-ray ptychography which allows studies under gas flow and at elevated temperature. In order to gain complementary information by transmission and scanning electron microscopy, the cell makes use of a Protochips E-chipTM which contains a small, thin electron transparent window and allows heating. Two gold-based systems, 50 nm gold particles and nanoporous gold as a relevant catalyst sample, were used for studying the feasibility of the cell. Measurements showing a resolution around 40 nm have been achieved under a flow of synthetic air and during heating up to temperatures of 933 K. An elevated temperature exhibited little influence on image quality and resolution. With this study, the potential of in situ hard X-ray ptychography for investigating annealing processes of real catalyst samples is demonstrated. Furthermore, the possibility to use the same sample holder for ex situ electron microscopy before and after the in situ study underlines the unique possibilities available with this combination of electron microscopy and X-ray microscopy on the same sample.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Difração de Raios X / Temperatura Alta / Pressão Hidrostática / Microscopia Idioma: En Revista: Microsc Microanal Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Difração de Raios X / Temperatura Alta / Pressão Hidrostática / Microscopia Idioma: En Revista: Microsc Microanal Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha