Your browser doesn't support javascript.
loading
The Performance of Vibration Controlled Transient Elastography in a US Cohort of Patients With Nonalcoholic Fatty Liver Disease.
Tapper, Elliot B; Challies, Tracy; Nasser, Imad; Afdhal, Nezam H; Lai, Michelle.
Afiliação
  • Tapper EB; Department of Medicine, Division of Gastroenterology and Hepatology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Challies T; Department of Pathology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Nasser I; Department of Pathology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Afdhal NH; Department of Medicine, Division of Gastroenterology and Hepatology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Lai M; Department of Medicine, Division of Gastroenterology and Hepatology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
Am J Gastroenterol ; 111(5): 677-84, 2016 05.
Article em En | MEDLINE | ID: mdl-26977758
OBJECTIVES: Identification of patients with nonalcoholic fatty liver disease (NAFLD) who have advanced fibrosis is crucial. Vibration controlled transient elastography (VCTE) is an alternative to biopsy, although published experience with VCTE in a US population is limited. METHODS: We performed a prospective cohort of 164 biopsy-proven NAFLD patients evaluated with VCTE using an M probe and the NAFLD fibrosis score (NFS) at baseline and a repeat VCTE at 6 months. Reliable liver stiffness measurements (LSMs) were defined as 10 valid measurements and interquartile range ≤30% of the median. RESULTS: A total of 120 (73.2%) patients had reliable LSM. The median LSMs for patients with and without F3-F4 (advanced) fibrosis were 6.6 kPA (5.3-8.9) and 14.4 kPA (12.1-24.3), respectively. The optimal LSM cutoff for advanced fibrosis was 9.9 kPA (sensitivity 95% and specificity 77%). In addition, 100% of patients with LSM<7.9 kPA did not have advanced fibrosis. A risk stratification strategy based on VCTE avoids the need for biopsy in at least the 74 (45.1%) patients correctly classified as low risk for advanced fibrosis. For the detection of F3-F4 fibrosis in patients with reliable VCTE, the area under the receiver operating curve (AUROC) is 0.93 (95% CI: 0.86-0.96). This is superior to the AUROC for the NFS (0.77), P=0.01. Patients who achieved a ≥5% weight loss at 6-month follow-up experienced improved LSM (P=0.009), independent of the changes in aminotransferase levels. CONCLUSIONS: Reliable VCTE results can rule out advanced fibrosis and avoid the need for biopsy in at least 45% of US patients with NAFLD. However, 1 in 4 patients have uninterpretable studies using the M probe.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade / Hepatopatia Gordurosa não Alcoólica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Am J Gastroenterol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade / Hepatopatia Gordurosa não Alcoólica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Am J Gastroenterol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos