Enantiomeric Separation of Chiral Pesticides by Permethylated ß-Cyclodextrin Stationary Phase in Reversed Phase Liquid Chromatography.
Chirality
; 28(5): 409-14, 2016 05.
Article
em En
| MEDLINE
| ID: mdl-26992448
Enantiomeric separation of six chiral pesticides by high-performance liquid chromatography with permethylated ß-cyclodextrin (ß-PM) chiral stationary phase were tested under reversed phase conditions. The influences of water composition from 10% to 45% in the mobile phase and column temperatures from 0°C to 40°C on the separation were investigated. Baseline separation was obtained for diclofop-methyl, fenoxaprop-ethyl, tebuconazole and triticonazole, and Rs of these pesticides were greater than 1.5. However, etoxazole and lactofen were partially separated in all experiments.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Praguicidas
/
Ciclodextrinas
/
Cromatografia de Fase Reversa
Idioma:
En
Revista:
Chirality
Assunto da revista:
BIOLOGIA MOLECULAR
/
QUIMICA
Ano de publicação:
2016
Tipo de documento:
Article
País de afiliação:
China