Your browser doesn't support javascript.
loading
Measuring medium-sized muscular arteries using a novel broadband 15-MHz linear array probe.
Yamada, Satoshi; Mikami, Taisei; Nishihara, Keiko; Mitake, Tsuyoshi; Izumi, Mikio; Yoshida, Naohiro; Hanaoka, Akihiko; Wu, Di; Komuro, Kaoru; Onozuka, Hisao; Fujii, Satoshi; Kitabatake, Akira.
Afiliação
  • Yamada S; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
  • Mikami T; College of Medical Technology, Hokkaido University, Kita 12, Nishi 5, Kitaku, 060-0812, Sapporo, Japan.
  • Nishihara K; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
  • Mitake T; Ultrasound Division, Hitachi Medical Corporation, 2-1 Shintoyofuta, 277-0804, Kashiwashi, Japan.
  • Izumi M; Ultrasound Division, Hitachi Medical Corporation, 2-1 Shintoyofuta, 277-0804, Kashiwashi, Japan.
  • Yoshida N; Ultrasound Division, Hitachi Medical Corporation, 2-1 Shintoyofuta, 277-0804, Kashiwashi, Japan.
  • Hanaoka A; Ultrasound Division, Hitachi Medical Corporation, 2-1 Shintoyofuta, 277-0804, Kashiwashi, Japan.
  • Wu D; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
  • Komuro K; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
  • Onozuka H; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
  • Fujii S; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
  • Kitabatake A; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita 15, Nishi 7, Kita-ku, 060-8638, Sapporo, Japan.
J Med Ultrason (2001) ; 30(3): 177-85, 2003 Sep.
Article em En | MEDLINE | ID: mdl-27278308
ABSTRACT
We recently developed a wideband 15-MHz linear array probe (15 M) with a band width of 8 MHz (9-17 MHz). Both axial and lateral resolution of 15 M, evaluated using a phantom model, were better than those of the current 10-MHz linear probe. To compare interobserver variability in measurement of medium-sized muscular arteries acquired using a 7.5-MHz linear probe (7.5 M), a 10-MHz linear probe (10M) and 15 M, two observers independently acquired images of the brachial and radial arteries, and measured the diameter and intima-media thickness (IMT) of those arteries in 17 male volunteers. Intraobserver variability in determining percent flowmediated dilatation (%FMD) was assessed in the same subjects using 15 M. Coefficients of variation (CV) in arteries measured using 7.5 M, 10 M, and 15 M were 7.0%, 2.5%, and 1.5%, respectively, for the diameter of the brachial artery; 10.3%, 5.8%, and 3.2%, respectively, for the diameter of the radial artery; and 17.0%, 13.8%, and 8.5%, respectively, for IMT of the far wall of the brachial artery. The CV of measurement of %FMD was 4.6%. The new 15-MHz probe thus warrants use in evaluating morphology and function of muscular arteries of medium size.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Med Ultrason (2001) Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Med Ultrason (2001) Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Japão