Determination of sulfonate ester genotoxic impurities in imatinib mesylate by gas chromatography with mass spectrometry.
Zhang, Chaozheng; Huang, Lin; Wu, Zhiguo; Chang, Chuanyou; Yang, Zhidong.
Afiliação
  • Zhang C; Key Laboratory of Ministry of Education Industrial Fermentation Microbiology, Tianjin Key Laboratory of Industrial Microbiology, College of Biotechnology, Tianjin University of Science & Technology, Tianjin, P. R. China. zhangchaozheng@tust.edu.cn.
  • Huang L; Key Laboratory of Ministry of Education Industrial Fermentation Microbiology, Tianjin Key Laboratory of Industrial Microbiology, College of Biotechnology, Tianjin University of Science & Technology, Tianjin, P. R. China.
  • Wu Z; College of Chemical Engineering and Materials Science, Tianjin University of Science & Technology, Tianjin, P. R. China.
  • Chang C; Key Laboratory of Ministry of Education Industrial Fermentation Microbiology, Tianjin Key Laboratory of Industrial Microbiology, College of Biotechnology, Tianjin University of Science & Technology, Tianjin, P. R. China.
  • Yang Z; TianJin WeiJie Technology Co. Ltd, Tianjin, P. R. China.
J Sep Sci ; 39(18): 3558-63, 2016 Sep.
Article em En | MEDLINE | ID: mdl-27461842
ABSTRACT
Methyl methanesulfonate and ethyl methanesulfonate are potential genotoxic impurities in imatinib mesylate. In this work, a simple, sensitive, reliable, and fast gas chromatography with mass spectrometry method for the simultaneous determination of methyl methanesulfonate and ethyl methanesulfonate was developed and validated. Total analysis time was only 7 min. An n-hexane/water solution was used to dissolve samples, and then extracted-ion-chromatogram mode was used to quantify methyl methanesulfonate and ethyl methanesulfonate. Calibration curves showed good linearity over the studied range for methyl methanesulfonate and ethyl methanesulfonate. The correlation coefficient of fit exceeded 0.999 for each impurity. The LOD and LOQ of methyl methanesulfonate and ethyl methanesulfonate were as low as 0.001 and 0.005 µg/mL, respectively, with RSDs of the peak area within 1.06-1.96%. Method accuracy was within 97.2-99.8% for methyl methanesulfonate and ethyl methanesulfonate. Therefore, this method can be used to quantify methyl methanesulfonate and ethyl methanesulfonate impurities at extremely low levels in imatinib mesylate.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Metanossulfonato de Etila / Mesilato de Imatinib / Cromatografia Gasosa-Espectrometria de Massas / Metanossulfonato de Metila / Mutagênicos Tipo de estudo: Evaluation_studies Idioma: En Revista: J Sep Sci Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Metanossulfonato de Etila / Mesilato de Imatinib / Cromatografia Gasosa-Espectrometria de Massas / Metanossulfonato de Metila / Mutagênicos Tipo de estudo: Evaluation_studies Idioma: En Revista: J Sep Sci Ano de publicação: 2016 Tipo de documento: Article