Your browser doesn't support javascript.
loading
Development of a normalized extraction to further aid in fast, high-throughput processing of forensic DNA reference samples.
Connon, Catherine C; LeFebvre, Aaron K; Benjamin, Robert C.
Afiliação
  • Connon CC; Virginia Commonwealth University, Department of Forensic Science, 1015 Floyd Ave Box 843079, Richmond, VA 23284, United States; Cellmark Forensics, Inc., a LabCorp Specialty Testing Group, 13988 Diplomat Drive, Suite 100, Farmers Branch, TX 75234, United States; University of North Texas, Department of Biological Sciences, 1155 Union Circle #305220, Denton, TX 76203-5017, United States. Electronic address: cmconnon@vcu.edu.
  • LeFebvre AK; Cellmark Forensics, Inc., a LabCorp Specialty Testing Group, 13988 Diplomat Drive, Suite 100, Farmers Branch, TX 75234, United States; Next Health LLC, 5710 Lyndon B Johnson Fwy #300, Dallas, TX 75240, United States.
  • Benjamin RC; University of North Texas, Department of Biological Sciences, 1155 Union Circle #305220, Denton, TX 76203-5017, United States.
Forensic Sci Int Genet ; 25: 112-124, 2016 11.
Article em En | MEDLINE | ID: mdl-27566134
ABSTRACT
The goal of this project was to develop a "normalized" extraction procedure to be used in conjunction with previously validated 3µL fast PCR reactions (42-51min utilizing KAPA2G™ Fast Multiplex PCR Kit) and alternative capillary electrophoresis (24-28min injection using POP-6™ Polymer and a 22cm array). This was the final phase of a workflow overhaul for the database unit at Cellmark Forensics to achieve a substantial reduction in processing time for forensic DNA database samples without incurring significant added costs and/or the need for new instrumentation, while still generating high quality STR profiles. Extraction normalization aimed to consistently yield a small range of DNA concentrations, thereby eliminating the need for sample quantification and dilution. This was specifically achieved using the ChargeSwitch® Forensic DNA Purification Kit and a reduction in extraction bead quantity, thereby forcing an increase in bead binding efficiency. Following development of this extraction procedure, an evaluation ensued to assess the combination of normalized extraction, 3µL fast PCR (with PowerPlex 16 HS, Identifiler Plus and Identifiler primer sets), and alternative CE detection - further referred to as new "first pass" procedures. These modifications resulted in a 37% reduction in processing time and were evaluated via an in depth validation, from which nearly 2000 STR profiles were generated, of which 554 profiles from 77 swab donors and 210 profiles from 35 buccal collector donors specifically arose from the new first pass procedures. This validation demonstrates the robustness of these processes for buccal swabs and Buccal DNA Collectors™ using the three primer sets evaluated and their ability to generate high quality STR profiles with 95-99% and 88-91% pass rates, respectively.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: DNA Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Forensic Sci Int Genet Assunto da revista: GENETICA / JURISPRUDENCIA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: DNA Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Forensic Sci Int Genet Assunto da revista: GENETICA / JURISPRUDENCIA Ano de publicação: 2016 Tipo de documento: Article