A Proposed Methodology to Assess the Accuracy of 3D Scanners and Casts and Monitor Tooth Wear Progression in Patients.
Int J Prosthodont ; 29(5): 514-21, 2016.
Article em En | MEDLINE | ID: mdl-27611759
ABSTRACT

PURPOSE:

The aim of this study was to detail and assess the capability of a novel methodology to 3D-quantify tooth wear progression in a patient over a period of 12 months. MATERIALS AND

METHODS:

A calibrated stainless steel model was used to identify the accuracy of the scanning system by assessing the accuracy and precision of the contact scanner and the dimensional accuracy and stability of casts fabricated from three different types of impression materials. Thereafter, the overall accuracy of the 3D scanning system (scanner and casts) was ascertained. Clinically, polyether impressions were made of the patient's dentition at the initial examination and at the 12-month review, then poured in type IV dental stone to assess the tooth wear. The anterior teeth on the resultant casts were scanned, and images were analyzed using 3D matching software to detect dimensional variations between the patient's impressions.

RESULTS:

The accuracy of the 3D scanning system was established to be 33 µm. 3D clinical analysis demonstrated localized wear on the incisal and palatal surfaces of the patient's maxillary central incisors. The identified wear extended to a depth of 500 µm with a distribution of 4% to 7% of affected tooth surfaces.

CONCLUSION:

The newly developed 3D scanning methodology was found to be capable of assessing and accounting for the various factors affecting tooth wear scanning. Initial clinical evaluation of the methodology demonstrates successful monitoring of tooth wear progression. However, further clinical assessment is needed.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento Tridimensional / Modelos Dentários / Desgaste dos Dentes / Imagem Óptica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Int J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento Tridimensional / Modelos Dentários / Desgaste dos Dentes / Imagem Óptica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Int J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2016 Tipo de documento: Article