Your browser doesn't support javascript.
loading
Photoacoustic mammography capable of simultaneously acquiring photoacoustic and ultrasound images.
Asao, Yasufumi; Hashizume, Yohei; Suita, Takahiro; Nagae, Ken-Ichi; Fukutani, Kazuhiko; Sudo, Yoshiaki; Matsushita, Toshikazu; Kobayashi, Shuichi; Tokiwa, Mariko; Yamaga, Iku; Fakhrejahani, Elham; Torii, Masae; Kawashima, Masahiro; Takada, Masahiro; Kanao, Shotaro; Kataoka, Masako; Shiina, Tsuyoshi; Toi, Masakazu.
Afiliação
  • Asao Y; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, JapanbKyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Hashizume Y; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Suita T; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Nagae KI; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Fukutani K; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Sudo Y; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Matsushita T; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Kobayashi S; Canon Inc., Medical Imaging Development Center, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 1468501, Japan.
  • Tokiwa M; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Yamaga I; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Fakhrejahani E; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Torii M; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Kawashima M; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Takada M; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Kanao S; Kyoto University, Graduate School of Medicine, Department of Diagnostic Imaging and Nuclear Medicine, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Kataoka M; Kyoto University, Graduate School of Medicine, Department of Diagnostic Imaging and Nuclear Medicine, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Shiina T; Kyoto University, Graduate School of Medicine, Department of Human Health Science, 53 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
  • Toi M; Kyoto University, Graduate School of Medicine, Department of Breast Surgery, 54 Shogoin-Kawaharacho Sakyo-ku, Kyoto 6068507, Japan.
J Biomed Opt ; 21(11): 116009, 2016 11 01.
Article em En | MEDLINE | ID: mdl-27893089
ABSTRACT
We have constructed a prototype photoacoustic mammography system (PAM-02) capable of simultaneously acquiring photoacoustic (PA) and ultrasound (US) images. Each PA, US, and fused PA/US image can be acquired over a wide area of the breast using the scanning module of a US transducer, a PA detector, and optical prisms. The resolution of the PA images exhibits improvement from 2 to 1 mm compared to images acquired using our previous prototype. The maximum scan area of PAM-02 is 90 mm along the horizontal axis and 150 mm along the vertical axis. In a phantom experiment, the available depth was at least 45 mm. A representative example of the application of the PAM-02 prototype in clinical research at Kyoto University is presented and shows S-factor images, which are considered an approximation parameter related to hemoglobin saturation of tumor-related blood vessels. We confirmed the applicability of the system for anatomical and biological research.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mamografia / Ultrassonografia / Técnicas Fotoacústicas Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mamografia / Ultrassonografia / Técnicas Fotoacústicas Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão