Your browser doesn't support javascript.
loading
Schinus terebinthifolius countercurrent chromatography (Part III): Method transfer from small countercurrent chromatography column to preparative centrifugal partition chromatography ones as a part of method development.
das Neves Costa, Fernanda; Hubert, Jane; Borie, Nicolas; Kotland, Alexis; Hewitson, Peter; Ignatova, Svetlana; Renault, Jean-Hugues.
Afiliação
  • das Neves Costa F; Universidade Federal do Rio de Janeiro, Instituto de Pesquisas de Produtos Naturais, Rio de Janeiro, Brazil. Electronic address: fncosta@nppn.ufrj.br.
  • Hubert J; UMR CNRS 7312, Institut de Chimie Moléculaire de Reims, Université de Reims Champagne-Ardenne, Reims, France.
  • Borie N; UMR CNRS 7312, Institut de Chimie Moléculaire de Reims, Université de Reims Champagne-Ardenne, Reims, France.
  • Kotland A; UMR CNRS 7312, Institut de Chimie Moléculaire de Reims, Université de Reims Champagne-Ardenne, Reims, France.
  • Hewitson P; Advanced Bioprocessing Centre, Institute of Environment, Health & Societies, CEDPS, Brunel University London, Middlesex, UB8 3PH, UK.
  • Ignatova S; Advanced Bioprocessing Centre, Institute of Environment, Health & Societies, CEDPS, Brunel University London, Middlesex, UB8 3PH, UK.
  • Renault JH; UMR CNRS 7312, Institut de Chimie Moléculaire de Reims, Université de Reims Champagne-Ardenne, Reims, France.
J Chromatogr A ; 1487: 77-82, 2017 Mar 03.
Article em En | MEDLINE | ID: mdl-28110947
ABSTRACT
Countercurrent chromatography (CCC) and centrifugal partition chromatography (CPC) are support free liquid-liquid chromatography techniques sharing the same basic principles and features. Method transfer has previously been demonstrated for both techniques but never from one to another. This study aimed to show such a feasibility using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. Heptane - ethyl acetate - methanol -water (6161, v/v/v/v) was used as solvent system with masticadienonic and 3ß-masticadienolic acids as target compounds. The optimized separation methodology previously described in Part I and II, was scaled up from an analytical hydrodynamic CCC column (17.4mL) to preparative hydrostatic CPC instruments (250mL and 303mL) as a part of method development. Flow-rate and sample loading were further optimized on CPC. Mobile phase linear velocity is suggested as a transfer invariant parameter if the CPC column contains sufficient number of partition cells.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Química Analítica / Cromatografia Líquida / Distribuição Contracorrente / Anacardiaceae Idioma: En Revista: J Chromatogr A Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Química Analítica / Cromatografia Líquida / Distribuição Contracorrente / Anacardiaceae Idioma: En Revista: J Chromatogr A Ano de publicação: 2017 Tipo de documento: Article