Measurement system for alpha and beta emitters with continuous air sampling under different exposure situations.
Yamada, Ryohei; Tamakuma, Yuki; Iwaoka, Kazuki; Hosoda, Masahiro; Shiroma, Yoshitaka; Akata, Naofumi; Mizuno, Hiroyuki; Yamada, Kouji; Kuroki, Tomohiro; Tokonami, Shinji.
Afiliação
  • Yamada R; Hirosaki University Graduate School of Health Sciences, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan.
  • Tamakuma Y; School of Health Sciences, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan.
  • Iwaoka K; Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan.
  • Hosoda M; Hirosaki University Graduate School of Health Sciences, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan.
  • Shiroma Y; National Institute for Fusion Science, 322-6 Oroshicho, Toki, Gifu 509-5292, Japan.
  • Akata N; National Institute for Fusion Science, 322-6 Oroshicho, Toki, Gifu 509-5292, Japan.
  • Mizuno H; Fuji Electric Co., Ltd., Gate City Ohsaki, East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan.
  • Yamada K; Fuji Electric Co., Ltd., Gate City Ohsaki, East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan.
  • Kuroki T; Fuji Electric Co., Ltd., Gate City Ohsaki, East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan.
  • Tokonami S; Hirosaki University Graduate School of Health Sciences, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan; Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan. Electronic address: tokonami@hirosaki-u.ac.jp.
Appl Radiat Isot ; 126: 79-82, 2017 Aug.
Article em En | MEDLINE | ID: mdl-28111091
In the present study, a continuous radioactive aerosol measurement system (CRAMS) was developed for measurements of radioactive plume (e.g. 131I, 134Cs and 137Cs) under the emergency situation, and measurements of radon/thoron progeny under the existing situation. As a result, it is suggested that the CRAMS could follow the variation of radon concentration, and the detection limit of the CRAMS under ambient dose equivalent rate of 20µSvh-1, where the temporary evacuation is required within one week in the Japanese regulation, was evaluated to be 129Bqm-3 in the manner of ISO11929.