Your browser doesn't support javascript.
loading
Successful Retrieval of an Entrapped Rotablator Burr by Using a Guideliner Guiding Catheter and a Snare.
Chiang, Chun-Hsien; Liu, Shih-Chi.
Afiliação
  • Chiang CH; Department of Cardiology, Far Eastern Memorial Hospital.
  • Liu SC; Division of Cardiology, Department of Internal Medicine, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan.
Acta Cardiol Sin ; 33(1): 96-98, 2017 Jan.
Article em En | MEDLINE | ID: mdl-28115813
ABSTRACT
Although burr entrapment is a rare complication of rotablation, it is extremely difficult to retrieve a stuck entrapped burr without surgical intervention. There are several techniques typically employed to retrieve an entrapped burr, using bailout endovascular approaches. Herein we have presented a new retrieval method involving a Guideliner child-in-mother catheter combined with a snare, which was used to successfully rescue a stuck rotablator burr.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Acta Cardiol Sin Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Acta Cardiol Sin Ano de publicação: 2017 Tipo de documento: Article