Continuous Flow 1H and 13C NMR Spectroscopy in Microfluidic Stripline NMR Chips.
Oosthoek-de Vries, Anna Jo; Bart, Jacob; Tiggelaar, Roald M; Janssen, Johannes W G; van Bentum, P Jan M; Gardeniers, Han J G E; Kentgens, Arno P M.
Afiliação
  • Oosthoek-de Vries AJ; Institute of Molecules and Materials, Radboud University , 6525 HP Nijmegen, The Netherlands.
  • Bart J; Institute of Molecules and Materials, Radboud University , 6525 HP Nijmegen, The Netherlands.
  • Tiggelaar RM; Mesoscale Chemical Systems, MESA+ Institute of Nanotechnology, University of Twente , 7522 NB Enschede, The Netherlands.
  • Janssen JW; Mesoscale Chemical Systems, MESA+ Institute of Nanotechnology, University of Twente , 7522 NB Enschede, The Netherlands.
  • van Bentum PJ; Institute of Molecules and Materials, Radboud University , 6525 HP Nijmegen, The Netherlands.
  • Gardeniers HJ; Institute of Molecules and Materials, Radboud University , 6525 HP Nijmegen, The Netherlands.
  • Kentgens AP; Mesoscale Chemical Systems, MESA+ Institute of Nanotechnology, University of Twente , 7522 NB Enschede, The Netherlands.
Anal Chem ; 89(4): 2296-2303, 2017 02 21.
Article em En | MEDLINE | ID: mdl-28194934
ABSTRACT
Microfluidic stripline NMR technology not only allows for NMR experiments to be performed on small sample volumes in the submicroliter range, but also experiments can easily be performed in continuous flow because of the stripline's favorable geometry. In this study we demonstrate the possibility of dual-channel operation of a microfluidic stripline NMR setup showing one- and two-dimensional 1H, 13C and heteronuclear NMR experiments under continuous flow. We performed experiments on ethyl crotonate and menthol, using three different types of NMR chips aiming for straightforward microfluidic connectivity. The detection volumes are approximately 150 and 250 nL, while flow rates ranging from 0.5 µL/min to 15 µL/min have been employed. We show that in continuous flow the pulse delay is determined by the replenishment time of the detector volume, if the sample trajectory in the magnet toward NMR detector is long enough to polarize the spin systems. This can considerably speed up quantitative measurement of samples needing signal averaging. So it can be beneficial to perform continuous flow measurements in this setup for analysis of, e.g., reactive, unstable, or mass-limited compounds.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda