Your browser doesn't support javascript.
loading
B1+ inhomogeneity mitigation in CEST using parallel transmission.
Tse, Desmond H Y; da Silva, Nuno Andre; Poser, Benedikt A; Shah, N Jon.
Afiliação
  • Tse DHY; Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.
  • da Silva NA; Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich GmbH, Wilhelm-Johnen-Strasse, Juelich, Germany.
  • Poser BA; Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.
  • Shah NJ; Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich GmbH, Wilhelm-Johnen-Strasse, Juelich, Germany.
Magn Reson Med ; 78(6): 2216-2225, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28244138
ABSTRACT

PURPOSE:

In order to benefit from the increased spectral bandwidth at ultrahigh field (UHF), the use of parallel transmission (pTx) to mitigate flip-angle inhomogeneity in chemical exchange saturation transfer (CEST) imaging is investigated. THEORY AND

METHODS:

A pTx basis pulse is homogenised by magnitude least-squares (MLS) optimization and expanded to form a frequency-selective saturation pulse for CEST. The pTx saturation pulse was simulated with a three-pool Bloch-McConnell equation to evaluate the impact of pTx on CEST contrast. In vivo CEST imaging performance (7 T) of the pTx saturation pulse and the standard Gaussian saturation in circularly polarized mode were compared. Two-spokes pTx homogeneous excitation was used in all in vivo experiments to ensure fair comparison of the two saturation pulses. Magnetization transfer ratio and inverse Z-spectrum analyses were used as metrics in evaluating the data from 3 healthy volunteers.

RESULTS:

Bloch-McConnell simulations showed that side bands of the pTx saturation pulse at ±20 ppm did not affect any CEST contrast. Improved homogeneity in contrasts and relaxation-compensated CEST metrics were observed in our in vivo data when the pTx saturation pulse was used.

CONCLUSION:

A pTx-based pulsed CEST presaturation scheme is proposed and validated by simulations and 7T in vivo imaging. Magn Reson Med 782216-2225, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda