Your browser doesn't support javascript.
loading
Fe3 N-Co2 N Nanowires Array: A Non-Noble-Metal Bifunctional Catalyst Electrode for High-Performance Glucose Oxidation and H2 O2 Reduction toward Non-Enzymatic Sensing Applications.
Zhou, Dan; Cao, Xiaoqin; Wang, Zao; Hao, Shuai; Hou, Xiandeng; Qu, Fengli; Du, Gu; Asiri, Abdullah M; Zheng, Chengbin; Sun, Xuping.
Afiliação
  • Zhou D; College of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
  • Cao X; College of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
  • Wang Z; College of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
  • Hao S; College of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
  • Hou X; College of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
  • Qu F; Analytical & Testing Center, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
  • Du G; College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, Shandong, P. R. China.
  • Asiri AM; Chengdu Institute of Geology and Mineral Resources, Chengdu, 610081, Sichuan, P. R. China.
  • Zheng C; Chemistry Department, King Abdulaziz University, Jeddah, 21589, Saudi Arabia.
  • Sun X; College of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, P. R. China.
Chemistry ; 23(22): 5214-5218, 2017 Apr 19.
Article em En | MEDLINE | ID: mdl-28266077
ABSTRACT
Among reported electrode materials, a nanoarray is an attractive architecture for molecular detection because of its large specific surface area and easy accessibility for target molecules. Here, a new Fe3 N-Co2 N nanowires array grown on carbon cloth (Fe3 N-Co2 N/CC) is reported as a non-noble-metal bifunctional catalyst electrode for high-performance glucose oxidation and H2 O2 reduction. As an electrochemical non-enzymatic sensor for glucose detection, Fe3 N-Co2 N/CC shows a fast response time of 8 s, a low detection limit (LOD) of 77 nm (signal/noise=3), and a high sensitivity of 4333.7 µA mm-1 cm-2 . As an H2 O2 sensor, it shows a LOD of 59 nm (signal/noise=3) and a sensitivity of 2273.8 µA mm-1 cm-2 with a response time of 2 s. In addition, the proposed sensor is stable with high selectivity, specificity, and reproducibility, and its application for real sample analysis has been successfully demonstrated.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Chemistry Assunto da revista: QUIMICA Ano de publicação: 2017 Tipo de documento: Article