A study of computer-aided diagnosis for pulmonary nodule: comparison between classification accuracies using calculated image features and imaging findings annotated by radiologists.
Int J Comput Assist Radiol Surg
; 12(5): 767-776, 2017 May.
Article
em En
| MEDLINE
| ID: mdl-28285338
ABSTRACT
PURPOSE:
In our previous study, we developed a computer-aided diagnosis (CADx) system using imaging findings annotated by radiologists. The system, however, requires radiologists to input many imaging findings. In order to reduce such an interaction of radiologists, we further developed a CADx system using derived imaging findings based on calculated image features, in which the system only requires few user operations. The purpose of this study is to check whether calculated image features (CFT) or derived imaging findings (DFD) can represent information in imaging findings annotated by radiologists (AFD).METHODS:
We calculate 2282 image features and derive 39 imaging findings by using information on a nodule position and its type (solid or ground-glass). These image features are categorized into shape features, texture features and imaging findings-specific features. Each imaging finding is derived based on each corresponding classifier using random forest. To check whether CFT or DFD can represent information in AFD, under an assumption that the accuracies of classifiers are the same if information included in input is the same, we constructed classifiers by using various types of information (CTT, DFD and AFD) and compared accuracies on an inferred diagnosis of a nodule. We employ SVM with RBF kernel as classifier to infer a diagnosis name.RESULTS:
Accuracies of classifiers using DFD, CFT, AFD and CFT [Formula see text] AFD were 0.613, 0.577, 0.773 and 0.790, respectively. Concordance rates between DFD and AFD of shape findings, texture findings and surrounding findings were 0.644, 0.871 and 0.768, respectively.CONCLUSIONS:
The results suggest that CFT and AFD are similar information and CFT represent only a portion of AFD. Particularly, CFT did not contain shape information in AFD. In order to decrease an interaction of radiologists, a development of a method which overcomes these problems is necessary.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Interpretação de Imagem Radiográfica Assistida por Computador
/
Tomografia Computadorizada por Raios X
/
Diagnóstico por Computador
/
Nódulo Pulmonar Solitário
/
Neoplasias Pulmonares
Tipo de estudo:
Diagnostic_studies
Limite:
Adolescent
/
Adult
/
Aged
/
Aged80
/
Child
/
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
Idioma:
En
Revista:
Int J Comput Assist Radiol Surg
Assunto da revista:
RADIOLOGIA
Ano de publicação:
2017
Tipo de documento:
Article
País de afiliação:
Japão