Integration of Single-Center Data-Driven Vital Sign Parameters into a Modified Pediatric Early Warning System.
Pediatr Crit Care Med
; 18(5): 469-476, 2017 May.
Article
em En
| MEDLINE
| ID: mdl-28338520
OBJECTIVES: Pediatric early warning systems using expert-derived vital sign parameters demonstrate limited sensitivity and specificity in identifying deterioration. We hypothesized that modified tools using data-driven vital sign parameters would improve the performance of a validated tool. DESIGN: Retrospective case control. SETTING: Quaternary-care children's hospital. PATIENTS: Hospitalized, noncritically ill patients less than 18 years old. Cases were defined as patients who experienced an emergent transfer to an ICU or out-of-ICU cardiac arrest. Controls were patients who never required intensive care. Cases and controls were split into training and testing groups. INTERVENTIONS: The Bedside Pediatric Early Warning System was modified by integrating data-driven heart rate and respiratory rate parameters (modified Bedside Pediatric Early Warning System 1 and 2). Modified Bedside Pediatric Early Warning System 1 used the 10th and 90th percentiles as normal parameters, whereas modified Bedside Pediatric Early Warning System 2 used fifth and 95th percentiles. MEASUREMENTS AND MAIN RESULTS: The training set consisted of 358 case events and 1,830 controls; the testing set had 331 case events and 1,215 controls. In the sensitivity analysis, 207 of the 331 testing set cases (62.5%) were predicted by the original tool versus 206 (62.2%; p = 0.54) with modified Bedside Pediatric Early Warning System 1 and 191 (57.7%; p < 0.001) with modified Bedside Pediatric Early Warning System 2. For specificity, 1,005 of the 1,215 testing set control patients (82.7%) were identified by original Bedside Pediatric Early Warning System versus 1,013 (83.1%; p = 0.54) with modified Bedside Pediatric Early Warning System 1 and 1,055 (86.8%; p < 0.001) with modified Bedside Pediatric Early Warning System 2. There was no net gain in sensitivity and specificity using either of the modified Bedside Pediatric Early Warning System tools. CONCLUSIONS: Integration of data-driven vital sign parameters into a validated pediatric early warning system did not significantly impact sensitivity or specificity, and all the tools showed lower than desired sensitivity and specificity at a single cutoff point. Future work is needed to develop an objective tool that can more accurately predict pediatric decompensation.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Unidades de Terapia Intensiva Pediátrica
/
Transferência de Pacientes
/
Sinais Vitais
/
Deterioração Clínica
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Child
/
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
/
Newborn
Idioma:
En
Revista:
Pediatr Crit Care Med
Assunto da revista:
PEDIATRIA
/
TERAPIA INTENSIVA
Ano de publicação:
2017
Tipo de documento:
Article