Your browser doesn't support javascript.
loading
Attogram mass sensing based on silicon microbeam resonators.
Baek, In-Bok; Byun, Sangwon; Lee, Bong Kuk; Ryu, Jin-Hwa; Kim, Yarkyeon; Yoon, Yong Sun; Jang, Won Ik; Lee, Seongjae; Yu, Han Young.
Afiliação
  • Baek IB; Department of Physics, Research Institute for Natural Sciences, Hanyang University, 222 Wangsimri-ro, Seongdonggu, Seoul, 04763, Korea.
  • Byun S; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
  • Lee BK; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
  • Ryu JH; Department of Electronics Engineering, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon, 22012, Korea.
  • Kim Y; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
  • Yoon YS; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
  • Jang WI; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
  • Lee S; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
  • Yu HY; Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeongno, Yuseong, Daejeon, 34129, Korea.
Sci Rep ; 7: 46660, 2017 04 21.
Article em En | MEDLINE | ID: mdl-28429793
ABSTRACT
Using doubly-clamped silicon (Si) microbeam resonators, we demonstrate sub-attogram per Hertz (ag/Hz) mass sensitivity, which is extremely high sensitivity achieved by micro-scale MEMS mass sensors. We also characterize unusual buckling phenomena of the resonators. The thin-film based resonator is composed of a Si microbeam surrounded by silicon nitride (SiN) anchors, which significantly improve performance by providing fixation on the microbeam and stabilizing oscillating motion. Here, we introduce two fabrication techniques to further improve the mass sensitivity. First, we minimize surface stress by depositing a sacrificial SiN layer, which prevents damage on the Si microbeam. Second, we modify anchor structure to find optimal design that allows the microbeam to oscillate in quasi-one dimensional mode while achieving high quality factor. Mass loading is conducted by depositing Au/Ti thin films on the local area of the microbeam surface. Using sequential mass loading, we test effects of changing beam dimensions, position of mass loading, and distribution of a metal film on the mass sensitivity. In addition, we demonstrate that microbeams suffer local micro-buckling and global buckling by excessive mass loading, which are induced by two different mechanisms. We also find that the critical buckling length is increased by additional support from the anchors.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2017 Tipo de documento: Article