Pharmacokinetic Comparison of a Unit Dose Dry Powder Inhaler with a Multidose Dry Powder Inhaler for Delivery of Fluticasone Furoate.
J Aerosol Med Pulm Drug Deliv
; 30(5): 332-338, 2017 Oct.
Article
em En
| MEDLINE
| ID: mdl-28463040
BACKGROUND: The unit dose dry powder inhaler (UD-DPI) is being considered as an alternative inhaler platform that, if developed, has the potential to improve access to inhaled respiratory medicines in developing countries. AIM: This study compared the systemic exposure of fluticasone furoate after delivery from the UD-DPI with that from the ELLIPTA® inhaler. METHODS: This open-label, five-way cross-over, randomized, single-dose study in healthy subjects evaluated fluticasone furoate systemic exposure of three dose strengths (using four inhalations), 4 × 80 µg [320 µg], 4 × 100 µg [400 µg], and 4 × 140 µg [560 µg]), and two percentages of drug in lactose blends (0.6% and 0.8% by weight) after delivery from the UD-DPI compared with systemic exposures from the ELLIPTA inhaler (4 × 100 µg [400 µg] dose, 0.8% lactose blend). The primary treatment comparisons were area under the concentration-time curve from time 0 to 6 hours [AUC0-6] and maximum plasma concentration [Cmax]. RESULTS: After single-dose administration of fluticasone furoate, systemic exposure was lower from all UD-DPI formulations versus the ELLIPTA inhaler in terms of both AUC0-6 [AUC0-6 geometric least squares mean (GLM) ratios confidence interval (90% CI) for: UD-DPI (400 µg 0.8% blend)/ELLIPTA: 0.61 (0.55-0.67) and Cmax GLM (90% CI) for: UD-DPI (400 µg 0.8% blend)/ELLIPTA: 0.56 (0.49-0.64)]. Systemic exposures were â¼10% lower for fluticasone furoate UD-DPI for the 0.8% blend versus the 0.6% blend [GLM ratio (90% CI); 0.90 (0.81-1.00) for AUC0-6 and 0.89 (0.77-1.01) for Cmax], and increasing doses of fluticasone furoate from the UD-DPI showed systemic exposures that were approximately dose proportional. All treatments were well tolerated. CONCLUSIONS: Fluticasone furoate systemic exposure was lower from the UD-DPI than from the ELLIPTA inhaler, but the UD-DPI formulations did demonstrate detectable systemic levels and approximate dose proportionality. Together with the good tolerability shown, these data support further evaluation of the UD-DPI as a potential device for delivering inhaled respiratory drugs.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Broncodilatadores
/
Sistemas de Liberação de Medicamentos
/
Androstadienos
Tipo de estudo:
Clinical_trials
/
Prognostic_studies
Limite:
Adolescent
/
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
J Aerosol Med Pulm Drug Deliv
Assunto da revista:
TERAPIA POR MEDICAMENTOS
Ano de publicação:
2017
Tipo de documento:
Article