Temperature sensitive liposomes combined with thermal ablation: Effects of duration and timing of heating in mathematical models and in vivo.
PLoS One
; 12(6): e0179131, 2017.
Article
em En
| MEDLINE
| ID: mdl-28604815
BACKGROUND: Temperature sensitive liposomes (TSL) are nanoparticles that rapidly release the contained drug at hyperthermic temperatures, typically above ~40°C. TSL have been combined with various heating modalities, but there is no consensus on required hyperthermia duration or ideal timing of heating relative to TSL administration. The goal of this study was to determine changes in drug uptake when heating duration and timing are varied when combining TSL with radiofrequency ablation (RF) heating. METHODS: We used computer models to simulate both RF tissue heating and TSL drug delivery, to calculate spatial drug concentration maps. We simulated heating for 5, 12 and 30 min for a single RF electrode, as well as three sequential 12 min ablations for 3 electrodes placed in a triangular array. To support simulation results, we performed porcine in vivo studies in normal liver, where TSL filled with doxorubicin (TSL-Dox) at a dose of 30 mg was infused over 30 min. Following infusion, RF heating was performed in separate liver locations for either 5 min (n = 2) or 12 min (n = 2). After ablation, the animal was euthanized, and liver extracted and frozen. Liver samples were cut orthogonal to the electrode axis, and fluorescence imaging was used to visualize tissue doxorubicin distribution. RESULTS: Both in vivo studies and computer models demonstrate a ring-shaped drug deposition within ~1 cm of the visibly coagulated tissue. Drug uptake directly correlated with heating duration. In computer simulations, drug concentration increased by a factor of 2.2x and 4.3x when heating duration was extended from 5 to either 12, or 30 minutes, respectively. In vivo, drug concentration was by a factor of 2.4x higher at 12 vs 5 min heating duration (7.1 µg/g to 3.0 µg/g). The computer models suggest that heating should be timed to maximize area under the curve of systemic plasma concentration of encapsulated drug. CONCLUSIONS: Both computer models and in vivo study demonstrate that tissue drug uptake directly correlates with heating duration for TSL based delivery. Computational models were able to predict the spatial drug delivery profile, and may serve as a valuable tool in understanding and optimizing drug delivery systems.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Temperatura
/
Hipertermia Induzida
/
Lipossomos
/
Modelos Teóricos
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
PLoS One
Assunto da revista:
CIENCIA
/
MEDICINA
Ano de publicação:
2017
Tipo de documento:
Article
País de afiliação:
Estados Unidos