Your browser doesn't support javascript.
loading
Is multidetector CT-based bone mineral density and quantitative bone microstructure assessment at the spine still feasible using ultra-low tube current and sparse sampling?
Mei, Kai; Kopp, Felix K; Bippus, Rolf; Köhler, Thomas; Schwaiger, Benedikt J; Gersing, Alexandra S; Fehringer, Andreas; Sauter, Andreas; Münzel, Daniela; Pfeiffer, Franz; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B; Baum, Thomas.
Afiliação
  • Mei K; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany. kai.mei@tum.de.
  • Kopp FK; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Bippus R; Philips GmbH Innovative Technologies, Research Laboratories, Hamburg, Germany.
  • Köhler T; Philips GmbH Innovative Technologies, Research Laboratories, Hamburg, Germany.
  • Schwaiger BJ; TUM Institute for Advanced Studies, Technische Universität München, Garching b. Munich, Germany.
  • Gersing AS; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Fehringer A; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Sauter A; Lehrstuhl für Biomedizinische Physik, Technische Universität München, Garching b. Munich, Germany.
  • Münzel D; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Pfeiffer F; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Rummeny EJ; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Kirschke JS; TUM Institute for Advanced Studies, Technische Universität München, Garching b. Munich, Germany.
  • Noël PB; Lehrstuhl für Biomedizinische Physik, Technische Universität München, Garching b. Munich, Germany.
  • Baum T; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
Eur Radiol ; 27(12): 5261-5271, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28639046
ABSTRACT

OBJECTIVE:

Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. MATERIALS AND

METHODS:

Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5.

RESULTS:

Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05).

CONCLUSION:

In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. KEY POINTS • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vértebras Torácicas / Densidade Óssea / Fraturas da Coluna Vertebral / Fraturas por Osteoporose / Tomografia Computadorizada Multidetectores / Vértebras Lombares Tipo de estudo: Guideline / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vértebras Torácicas / Densidade Óssea / Fraturas da Coluna Vertebral / Fraturas por Osteoporose / Tomografia Computadorizada Multidetectores / Vértebras Lombares Tipo de estudo: Guideline / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha