Your browser doesn't support javascript.
loading
Subharmonic and Endoscopic Contrast Imaging of Pancreatic Masses: A Pilot Study.
Forsberg, Flemming; Stanczak, Maria; Lyshchik, Andrej; Loren, David; O'Kane, Patrick; Siddiqui, Ali; Kowalski, Thomas E; Miller, Cynthia; Fox, Traci; Liu, Ji-Bin; Eisenbrey, John R.
Afiliação
  • Forsberg F; Departments of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Stanczak M; Departments of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Lyshchik A; Departments of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Loren D; Gastroenterology and Hepatology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • O'Kane P; Departments of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Siddiqui A; Gastroenterology and Hepatology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Kowalski TE; Gastroenterology and Hepatology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Miller C; Gastroenterology and Hepatology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Fox T; Radiologic Sciences, Jefferson College of Health Professions, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Liu JB; Departments of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Eisenbrey JR; Departments of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
J Ultrasound Med ; 37(1): 123-129, 2018 Jan.
Article em En | MEDLINE | ID: mdl-28681437
ABSTRACT

OBJECTIVES:

To use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results.

METHODS:

Sixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD α-10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8 mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement.

RESULTS:

One patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (mean ± SD, 1.71 ± 1.63 versus 0.63 ± 0.89; P = .016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P > .60). The accuracies for contrast EUS and SHI were low (<53%), albeit with a greater κ value for SHI (0.34) than for EUS (0.13).

CONCLUSIONS:

Diagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Pancreáticas / Aumento da Imagem / Meios de Contraste / Endossonografia Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Pancreáticas / Aumento da Imagem / Meios de Contraste / Endossonografia Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos