Your browser doesn't support javascript.
loading
A Radio Frequency Radiation Exposure System for Rodents based on Reverberation Chambers.
Capstick, Myles; Kuster, Niels; Kuehn, Sven; Berdinas-Torres, Veronica; Gong, Yijian; Wilson, Perry; Ladbury, John; Koepke, Galen; McCormick, David L; Gauger, James; Melnick, Ronald L.
Afiliação
  • Capstick M; IT'IS Foundation, Zeughausstrasse 43, 8006 Zurich, Switzerland.
  • Kuster N; IT'IS Foundation and the Swiss Federal Institute of Technology, Switzerland.
  • Kuehn S; IT'IS Foundation, Zeughausstrasse 43, 8006 Zurich, Switzerland.
  • Berdinas-Torres V; IT'IS Foundation, Zeughausstrasse 43, 8006 Zurich, Switzerland.
  • Gong Y; IT'IS Foundation, Zeughausstrasse 43, 8006 Zurich, Switzerland.
  • Wilson P; NIST, 325 Broadway, Boulder, CO 80305, USA.
  • Ladbury J; NIST, 325 Broadway, Boulder, CO 80305, USA.
  • Koepke G; NIST, 325 Broadway, Boulder, CO 80305, USA.
  • McCormick DL; IIT Research Institute, 10 West 35th Street, Chicago, IL 60616, USA.
  • Gauger J; IIT Research Institute, 10 West 35th Street, Chicago, IL 60616, USA.
  • Melnick RL; North Logan, UT, 84341 USA. (formerly of NTP/NIEHS).
IEEE Trans Electromagn Compat ; 59(4): 1041-1052, 2017 Aug.
Article em En | MEDLINE | ID: mdl-29217848
ABSTRACT
In this paper we present the novel design features, their technical implementation, and an evaluation of the radio Frequency (RF) exposure systems developed for the National Toxicology Program (NTP) of the National Institute of Environmental Health Sciences (NIEHS) studies on the potential toxicity and carcinogenicity of 2nd and 3rd generation mobile-phone signals. The system requirements for this 2-year NTP cancer bioassay study were the tightly-controlled lifetime exposure of rodents (1568 rats and 1512 mice) to three power levels plus sham simulating typical daily, and higher, exposures of users of GSM and CDMA (IS95) signals. Reverberation chambers and animal housing were designed to allow extended exposure time per day for free-roaming individually-housed animals. The performance of the chamber was characterized in terms of homogeneity, stirred to unstirred energy, efficiency. The achieved homogeneity was 0.59 dB and 0.48 dB at 900 and 1900 MHz respectively. The temporal variation in the electric field strength was optimized to give similar characteristics to that of the power control of a phone in a real network using the two stirrers. Experimental dosimetry was performed to validate the SAR sensitivity and determine the SAR uniformity throughout the exposure volume; SAR uniformities of 0.46 dB and 0.40 dB, respectively, for rats and mice were achieved.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: IEEE Trans Electromagn Compat Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: IEEE Trans Electromagn Compat Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Suíça