Your browser doesn't support javascript.
loading
Aggregation-Induced Emission Probe for Specific Turn-On Quantification of Soluble Transferrin Receptor: An Important Disease Marker for Iron Deficiency Anemia and Kidney Diseases.
Zhang, Ruoyu; Sung, Simon H P; Feng, Guangxue; Zhang, Chong-Jing; Tang, Ben Zhong; Liu, Bin.
Afiliação
  • Zhang R; Department of Chemical and Biomolecular Engineering, National University of Singapore , 4 Engineering Drive 4, Singapore 117585.
  • Sung SHP; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Centre for Tissue Restoration and Reconstruction, HKUST Jockey Club Institute for Advanced Study, Institute of Molecular Functional Materials, Division of Biomedical Engineering, State Key Laboratory of Molecular Neur
  • Feng G; Department of Chemical and Biomolecular Engineering, National University of Singapore , 4 Engineering Drive 4, Singapore 117585.
  • Zhang CJ; Department of Chemical and Biomolecular Engineering, National University of Singapore , 4 Engineering Drive 4, Singapore 117585.
  • Kenry; Department of Chemical and Biomolecular Engineering, National University of Singapore , 4 Engineering Drive 4, Singapore 117585.
  • Tang BZ; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Centre for Tissue Restoration and Reconstruction, HKUST Jockey Club Institute for Advanced Study, Institute of Molecular Functional Materials, Division of Biomedical Engineering, State Key Laboratory of Molecular Neur
  • Liu B; SCUT-HKUST Joint Research Laboratory, Guangdong Innovative Research Team, State Key Laboratory of Luminescent Materials & Devices, South China University of Technology , Guangzhou 510640, China.
Anal Chem ; 90(2): 1154-1160, 2018 01 16.
Article em En | MEDLINE | ID: mdl-29271190
ABSTRACT
Transferrin receptor (TfR) is overexpressed on the surface of many cancer cells due to its vital roles in iron circulation and cellular respiration. Soluble transferrin receptor (sTfR), a truncated extracellular form of TfR in serum, is an important marker of iron deficiency anemia (IDA) and bone marrow failure in cancer patients. More recently, sTfR level in urine has been related to a specific kidney disease of Henoch-Schönlein purpura nephritis (HSPN). Despite the universal significance of sTfR, there is still a lack of a simple and sensitive method for the quantification of sTfR. Furthermore, it is desirable to have a probe that can detect both TfR and sTfR for further comparison study. In this work, we developed a water-soluble AIE-peptide conjugate with aggregation-induced emission (AIE) characteristics. Taking advantage of the negligible emission from molecularly dissolved tetraphenylethene (TPE), probe TPE-2T7 was used for the light-up detection of sTfR. The probe itself is nonemissive in aqueous solution, but it turns on its fluorescence upon interaction with sTfR to yield a detection limit of 0.27 µg/mL, which is much lower than the sTfR level in IDA patients. Furthermore, a proof-of-concept experiment validates the potential of the probe for diagnosis of HSPN by urine test.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Receptores da Transferrina / Anemia Ferropriva / Nefropatias Limite: Animals / Humans Idioma: En Revista: Anal Chem Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Receptores da Transferrina / Anemia Ferropriva / Nefropatias Limite: Animals / Humans Idioma: En Revista: Anal Chem Ano de publicação: 2018 Tipo de documento: Article