Your browser doesn't support javascript.
loading
Quantification of Myocardial Perfusion Defect Size in Rats: Comparison between Quantitative Perfusion SPECT and Autoradiography.
Wakabayashi, Hiroshi; Taki, Junichi; Inaki, Anri; Hiromasa, Tomo; Okuda, Koichi; Shibutani, Takayuki; Shiba, Kazuhiro; Kinuya, Seigo.
Afiliação
  • Wakabayashi H; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan. wakabayashi@staff.kanazawa-u.ac.jp.
  • Taki J; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Inaki A; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Hiromasa T; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Okuda K; Department of Physics, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Kahoku, Ishikawa, 920-0293, Japan.
  • Shibutani T; Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
  • Shiba K; Division of Tracer Kinetics, Advanced Science Research Center, Kanazawa University, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Kinuya S; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
Mol Imaging Biol ; 20(4): 544-550, 2018 08.
Article em En | MEDLINE | ID: mdl-29340889
ABSTRACT

PURPOSE:

Ultra-high resolution single-photon emission computed tomography (SPECT) system, using multiple pinhole collimators, has been applied to the imaging of small rodents. We aimed to compare the myocardial infarction (MI) area on quantitative perfusion single-photon emission computed tomography (QPS; Cedars-Sinai Medical Center, USA) with that on high-resolution autoradiography in rat model to determine the accuracy of perfusion defect measurement by QPS. PROCEDURES After thoracotomy, rats (n = 9) had their left coronary arteries occluded and reperfused before injection with 185 MBq [99mTc] methoxyisobutylisonitrile ([99mTc]MIBI) for SPECT and autoradiography. Healthy rats (n = 28) were similarly scanned to create a normal database on which to base QPS. The MI area on SPECT images was analysed automatically by QPS software. For the autoradiography images, regions of interest for MI were set at 1 mm intervals.

RESULTS:

In normal rats, [99mTc]MIBI accumulated throughout the left ventricles, and a polar map of ventricular perfusion showed the lowest and highest uptakes in the inferior (68 % ± 4 %) and anterior (92 % ± 5 %) walls, respectively. In the rat MI model, the percentage of polar map with reduced [99mTc]MIBI uptake correlated strongly with the percentage of left ventricle with MI on autoradiography (r2 = 0.90).

CONCLUSIONS:

QPS can quantitatively evaluate MI severity on myocardial perfusion images in rats, with comparable results to autoradiography. This widely available software could promote the development of new techniques for analysing cardiac images in small animals.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Perfusão / Autorradiografia / Tomografia Computadorizada de Emissão de Fóton Único / Infarto do Miocárdio Limite: Animals Idioma: En Revista: Mol Imaging Biol Assunto da revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Perfusão / Autorradiografia / Tomografia Computadorizada de Emissão de Fóton Único / Infarto do Miocárdio Limite: Animals Idioma: En Revista: Mol Imaging Biol Assunto da revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão