Your browser doesn't support javascript.
loading
Effect of cross-match on packed cell volume after transfusion of packed red blood cells in transfusion-naïve anemic cats.
Sylvane, Brittany; Prittie, Jennifer; Hohenhaus, Ann E; Tozier, Erik.
Afiliação
  • Sylvane B; Department of Emergency and Critical Care, The Animal Medical Center, New York.
  • Prittie J; Department of Emergency and Critical Care, The Animal Medical Center, New York.
  • Hohenhaus AE; The Cancer Institute, The Animal Medical Center, New York.
  • Tozier E; Lamb Statistical Consulting LLC, West Saint Paul, Minnesota.
J Vet Intern Med ; 32(3): 1077-1083, 2018 May.
Article em En | MEDLINE | ID: mdl-29573055
BACKGROUND: Novel feline RBC antigens might contribute to decreased efficacy of RBC transfusion and increased incidence of acute transfusion reactions (ATR). OBJECTIVES: To examine the effect of major cross-match in transfusion-naïve anemic cats on the incidence of acute immunologic transfusion reaction and transfusion efficacy for up to 24 hours after transfusion. ANIMALS: Forty-eight client owned transfusion-naïve anemic cats. METHODS: Prospective, randomized, controlled study. All transfusion-naïve cats receiving packed red blood cells (pRBC) transfusions from January 2016 to August 2017 were eligible for inclusion. Cats in the study group received cross-match and blood type compatible pRBCs and cats in the control group received noncross-matched blood type compatible pRBCs. Incidence of ATR and change in PCV after transfusion was recorded. RESULTS: No significant difference in incidence of transfusion reactions between cross-matched and noncross-matched groups (CM+ 4/24; 17%, CM- 7/24; 29%, P = .16). No significant difference between groups in mean change in PCV after transfusion scaled to dose of pRBCs administered at any time point after transfusion (immediate: CM+ 0.62 ± 0.59, CM- 0.75 ± 0.48, P = .41; 1 hour: CM+ 0.60 ± 0.66, CM- 0.74 ± 0.53, P = .43; 12 hours: CM+ 0.70 ± 0.55, CM- 0.66 ± 0.60, P = .81; 24 hours: CM+ 0.64 ± 0.71, CM- 0.55 ± 0.48, P = .70). CONCLUSIONS AND CLINICAL IMPORTANCE: Our results do not support use of the major cross-match test to increase efficacy of, and to decrease adverse events associated with, RBC transfusion in AB blood typed transfusion-naïve cats.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transfusão de Sangue / Tipagem e Reações Cruzadas Sanguíneas / Doenças do Gato / Hematócrito / Anemia Limite: Animals Idioma: En Revista: J Vet Intern Med Assunto da revista: MEDICINA INTERNA / MEDICINA VETERINARIA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transfusão de Sangue / Tipagem e Reações Cruzadas Sanguíneas / Doenças do Gato / Hematócrito / Anemia Limite: Animals Idioma: En Revista: J Vet Intern Med Assunto da revista: MEDICINA INTERNA / MEDICINA VETERINARIA Ano de publicação: 2018 Tipo de documento: Article