"What Is a Step?" Differences in How a Step Is Detected among Three Popular Activity Monitors That Have Impacted Physical Activity Research.
John, Dinesh; Morton, Alvin; Arguello, Diego; Lyden, Kate; Bassett, David.
Afiliação
  • John D; Department of Health Sciences, Northeastern University, Boston, MA 02115, USA. d.john@neu.edu.
  • Morton A; Department of Kinesiology, Recreation, and Sport Studies, University of Tennessee, Knoxville, TN 37996 USA. amorto16@vols.utk.edu.
  • Arguello D; Department of Health Sciences, Northeastern University, Boston, MA 02115, USA. arguello.d@husky.neu.edu.
  • Lyden K; KAL Research/Consulting, Denver, CO 80206, USA. katelyden6@gmail.com.
  • Bassett D; Department of Kinesiology, Recreation, and Sport Studies, University of Tennessee, Knoxville, TN 37996 USA. dbassett@utk.edu.
Sensors (Basel) ; 18(4)2018 Apr 15.
Article em En | MEDLINE | ID: mdl-29662048
(1) Background: This study compared manually-counted treadmill walking steps from the hip-worn DigiwalkerSW200 and OmronHJ720ITC, and hip and wrist-worn ActiGraph GT3X+ and GT9X; determined brand-specific acceleration amplitude (g) and/or frequency (Hz) step-detection thresholds; and quantified key features of the acceleration signal during walking. (2) Methods: Twenty participants (Age: 26.7 ± 4.9 years) performed treadmill walking between 0.89-to-1.79 m/s (2-4 mph) while wearing a hip-worn DigiwalkerSW200, OmronHJ720ITC, GT3X+ and GT9X, and a wrist-worn GT3X+ and GT9X. A DigiwalkerSW200 and OmronHJ720ITC underwent shaker testing to determine device-specific frequency and amplitude step-detection thresholds. Simulated signal testing was used to determine thresholds for the ActiGraph step algorithm. Steps during human testing were compared using bias and confidence intervals. (3) Results: The OmronHJ720ITC was most accurate during treadmill walking. Hip and wrist-worn ActiGraph outputs were significantly different from the criterion. The DigiwalkerSW200 records steps for movements with a total acceleration of ≥1.21 g. The OmronHJ720ITC detects a step when movement has an acceleration ≥0.10 g with a dominant frequency of ≥1 Hz. The step-threshold for the ActiLife algorithm is variable based on signal frequency. Acceleration signals at the hip and wrist have distinctive patterns during treadmill walking. (4) Conclusions: Three common research-grade physical activity monitors employ different step-detection strategies, which causes variability in step output.