Your browser doesn't support javascript.
loading
Fluoride-fiber-based side-pump coupler for high-power fiber lasers at 2.8 µm.
Opt Lett ; 43(10): 2340-2343, 2018 May 15.
Article em En | MEDLINE | ID: mdl-29762587
A side-pump coupler made of fluoride fibers was fabricated and tested. The tested device had a coupling efficiency of 83% and was driven with an incident pump power of up to 83.5 W, demonstrating high-power operation. Stable laser output of 15 W at a wavelength of around 2.8 µm was achieved over 1 h when using an erbium-doped double-clad fiber as the active medium. To the best of our knowledge, this is the first time a fluoride-glass-fiber-based side-pump coupler has been developed. A test with two devices demonstrated further power scalability.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Opt Lett Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Opt Lett Ano de publicação: 2018 Tipo de documento: Article