Your browser doesn't support javascript.
loading
Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples.
Hernandez, D R; Wolk, D M; Walker, K L; Young, S; Dunn, R; Dunbar, S A; Rao, A.
Afiliação
  • Hernandez DR; Geisinger Health, Danville, Pennsylvania, USA drhernandez@geisinger.edu.
  • Wolk DM; Geisinger Health, Danville, Pennsylvania, USA.
  • Walker KL; Scott and White Medical Center, Baylor Scott and White Health, Temple, Texas, USA.
  • Young S; TriCore Reference Laboratories, Albuquerque, New Mexico, USA.
  • Dunn R; Luminex Corporation, Austin, Texas, USA.
  • Dunbar SA; Luminex Corporation, Austin, Texas, USA.
  • Rao A; Scott and White Medical Center, Baylor Scott and White Health, Temple, Texas, USA.
J Clin Microbiol ; 56(8)2018 08.
Article em En | MEDLINE | ID: mdl-29848562
The vertical transmission of group B Streptococcus (GBS) strains causing neonatal sepsis is one of the leading reasons for neonatal mortality worldwide. The gold standard for GBS detection is enriched culture with or without the aid of chromogenic agars. Given the high risk for morbidity and mortality in this population, high assay sensitivity is required to prevent the personal and economic costs of GBS disease. Nucleic acid amplification tests (NAATs) allow for objective determination of GBS colonization with a sensitivity and a specificity higher than those of traditional culture methods. In this study, we determined the analytical and clinical performance of the Aries GBS assay compared to those of the enrichment culture method, biochemical identification, and the NAATs used at the study sites. Remnant Lim broth samples were used to perform the Aries assay and reference testing. Upon first testing using enriched culture as the reference standard, the Aries GBS assay identified GBS with a 96.1% sensitivity (95% confidence interval [CI], 91.2 to 98.7%) and a 91.4% specificity (95% CI, 88.8 to 93.6%). The test performed with 100% positive agreement (95% CI, 83.2 to 100%) compared to the results of the BD Max GBS assay and 98.0% positive agreement (95% CI, 89.2 to 99.9%) compared to the results of the Cepheid Xpert GBS LB test. Repeatability and reproducibility were maintained in intra- and interlaboratory testing, regardless of the instrument, module, or user who performed the test. The Aries GBS assay can be set up in less than 5 min and produces results in 2 h. The easy setup, with minimal hands-on time, and high assay sensitivity and specificity make this a useful testing option for GBS screening in prepartum women.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Infecciosas na Gravidez / Diagnóstico Pré-Natal / Infecções Estreptocócicas / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: J Clin Microbiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Infecciosas na Gravidez / Diagnóstico Pré-Natal / Infecções Estreptocócicas / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: J Clin Microbiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos