Your browser doesn't support javascript.
loading
A Hydrogel Meniscal Replacement: Knee Joint Pressure and Distribution in an Ovine Model Compared to Native Tissue.
Fischenich, Kristine M; Pauly, Hannah M; Lewis, Jackson T; Bailey, Travis S; Haut Donahue, Tammy L.
Afiliação
  • Fischenich KM; School of Biomedical Engineering, Colorado State University, Fort Collins, CO, 80523, USA.
  • Pauly HM; School of Biomedical Engineering, Colorado State University, Fort Collins, CO, 80523, USA.
  • Lewis JT; School of Biomedical Engineering, Colorado State University, Fort Collins, CO, 80523, USA.
  • Bailey TS; School of Biomedical Engineering, Colorado State University, Fort Collins, CO, 80523, USA.
  • Haut Donahue TL; Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO, 80523, USA.
Ann Biomed Eng ; 46(11): 1785-1796, 2018 Nov.
Article em En | MEDLINE | ID: mdl-29922953
ABSTRACT
Pressure distribution of the native ovine knee meniscus was compared to a medial meniscectomy and three treatment conditions including a suture reattachment of the native tissue, an allograft, and a novel thermoplastic elastomer hydrogel (TPE) construct. The objective of this study was to assess the efficacy of a novel TPE hydrogel construct at restoring joint pressure and distribution. Limbs were loaded in uniaxial compression at 45°, 60°, and 75° flexion and from 0 to 181 kg. The medial meniscectomy decreased contact area by approximately 50% and doubled the mean and maximum pressure reading for the medial hemijoint. No treatment condition tested within this study was able to fully restore medial joint contact area and pressures to the native condition. A decrease in lateral contact area and increase in pressures with the meniscectomy was also seen; and to some degree, all reattachment and replacement conditions including the novel TPE hydrogel replacement helped to restore lateral pressures. Although the TPE construct did not perform as well as hoped in the medial compartment, it performed as well as, if not better, than the other reattachment and replacement options in the lateral. Further work is necessary to determine the best anchoring and attachment methods.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Hidrogéis / Elastômeros / Menisco / Articulação do Joelho Limite: Animals Idioma: En Revista: Ann Biomed Eng Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Hidrogéis / Elastômeros / Menisco / Articulação do Joelho Limite: Animals Idioma: En Revista: Ann Biomed Eng Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos