Your browser doesn't support javascript.
loading
Three-Dimensional Registration of Freehand-Tracked Ultrasound to CT Images of the Talocrural Joint.
Tümer, Nazli; Kok, Aimee C; Vos, Frans M; Streekstra, Geert J; Askeland, Christian; Tuijthof, Gabrielle J M; Zadpoor, Amir A.
Afiliação
  • Tümer N; Department of Biomechanical Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD Delft, The Netherlands. n.sarkalkan-1@tudelft.nl.
  • Kok AC; Orthopaedic Research Center Amsterdam, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. a.kok@amc.uva.nl.
  • Vos FM; Department of Imaging Science and Technology, Quantitative Imaging Group, Delft University of Technology (TU Delft), Lorentzweg 1, 2628 CJ Delft, The Netherlands. f.m.vos@tudelft.nl.
  • Streekstra GJ; Department of Radiology, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. f.m.vos@tudelft.nl.
  • Askeland C; Department of Radiology, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. g.j.streekstra@amc.uva.nl.
  • Tuijthof GJM; SINTEF Medical Technology, 7465 Trondheim, Norway. christian.askeland@gmail.com.
  • Zadpoor AA; Orthopaedic Research Center Amsterdam, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. gabrielle.tuijthof@zuyd.nl.
Sensors (Basel) ; 18(7)2018 Jul 21.
Article em En | MEDLINE | ID: mdl-30037099
ABSTRACT
A rigid surface⁻volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD' arthroscopic accessibility, given the fact that 51% of the talar surface could be visualized.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Ultrassonografia / Imageamento Tridimensional / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Ultrassonografia / Imageamento Tridimensional / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Sensors (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Holanda