Your browser doesn't support javascript.
loading
First clinical evaluation of the new single-use flexible and semirigid Pusen ureteroscopes.
Emiliani, Esteban; Mercadé, Asier; Millan, Félix; Sánchez-Martín, Francisco; Konstantinidis, Cristian Andrés; Angerri, Oriol.
Afiliação
  • Emiliani E; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Mercadé A; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Millan F; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Sánchez-Martín F; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Konstantinidis CA; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Angerri O; Department of Urology, Fundació Puigvert, Universitat Autònoma de Barcelona, Barcelona, Spain.
Cent European J Urol ; 71(2): 208-213, 2018.
Article em En | MEDLINE | ID: mdl-30038812
INTRODUCTION: The purpose of the present study was to clinically evaluate two new single-use Pusen ureteroscopes, one semirigid with a flexible tip (srURS) and one flexible (fURS). MATERIALS AND METHODS: During ten consecutive procedures (five srURS and five fURS), we subjectively evaluated on a scale from 0 (poor) to 10 (excellent), the scope's deflection, image quality, and maneuverability prior to, during and after the surgery. Patient demographics, complications with the devices, and troubleshooting were recorded. RESULTS: There were a total of ten patients, five of which were female while the other five were male. Mean age was 58.9 years. Seven patients had a single kidney stone with mean size of 9.6 mm (1.6-20 mm). Half of the patients were pre-stented. For the fURS, the preoperative image quality rating was 8.4 (8-10), compared with 6.8 (4-9) during surgery. The preoperative deflection rating was 9.6+ 0.9 (8-10), while during surgery this decreased to 8.0 (6-10) and to 6.0 (4-8) when using a laser fiber. The srURS had a preoperative image quality rating of 9.2 (8-10), which decreased to 7.6 (6-9) while using the scope. The deflection rating decreased from 9.4 (7-10) preoperatively to 7.0 (1-10) postoperatively, and a similar reduction was observed in the maneuverability rating, from 9.6 (8-10) to 7.4 (1-10). Ureteroscopy was considered as a standard in four of the fURS and three of the srURS procedures. The mean overall satisfaction rating was 6. CONCLUSIONS: The two new single-use ureteroscopes, one flexible and one semirigid, were considered to have allowed standard ureteroscopy in four and three out of the five procedures for each scope, respectively. The image quality, deflection, and maneuverability ratings decreased during the procedure for both scopes.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Cent European J Urol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Cent European J Urol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Espanha