Your browser doesn't support javascript.
loading
[Assessment of iodine nutritional status for pregnant women using adjusted urine creatinine from spot and 24-hour urine].
Liu, Xiaobing; Wu, Meng; Zhang, Yu; Lu, Jiaxi; Piao, Jianhua; Yang, Lichen; Yang, Xiaoguang.
Afiliação
  • Liu X; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Wu M; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Zhang Y; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Lu J; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Piao J; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Yang L; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
  • Yang X; Key Laboratory of Trace Element Nutrition of National Health and Family Planning Commission, National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
Wei Sheng Yan Jiu ; 47(4): 548-553, 2018 Jul.
Article em Zh | MEDLINE | ID: mdl-30081979
OBJECTIVE: To establish a reliable method of iodine nutritional assessment for pregnant women using the adjusted urinary creatinine of spot urine and 24-hour urine samples. METHODS: The spot urine in the morning at 8 00-11:30 and the following 24-hour urine samples of pregnant women were collected in Peking Union Medical College Hospital during March to October in 2016. The urinary iodine and urinary creatinine concentrations were determined. The estimated 24-hour urinary iodine excretion( 24-h UIE) was calculated using the urinary iodine/urinary creatinine( UIC/Cr) ratio of spot urine, and 24-hour urinary creatinine excretion( 24-h UCr E). RESULTS: There was a significant difference in the UIC, UIC/Cr ratio between spot urine and 24-h urine( P <0. 05). The UIC, UIC/Cr ratio of spot urine, and the estimated 24-h UIE all were significantly correlated with the real 24-h UIE( P < 0. 01), especially the estimated 24-h UIE were taking up 70%-80% for the real 24-h UIE in the period of gestation. CONCLUSION: The UIC, UIC/Cr, and the estimated 24-h UIE cannot directly replace the relevant values derived of the 24-hour urine samples. But the estimated 24-h UIE can reflect the iodine nutritional status of pregnant women in recent days, and the method could be a reliable reference for the iodine nutritional assessment of the pregnant women in practice.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Estado Nutricional / Urinálise / Creatinina / Gestantes / Iodo Limite: Female / Humans / Pregnancy Idioma: Zh Revista: Wei Sheng Yan Jiu Assunto da revista: SAUDE PUBLICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China
Buscar no Google
Base de dados: MEDLINE Assunto principal: Estado Nutricional / Urinálise / Creatinina / Gestantes / Iodo Limite: Female / Humans / Pregnancy Idioma: Zh Revista: Wei Sheng Yan Jiu Assunto da revista: SAUDE PUBLICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China