Your browser doesn't support javascript.
loading
Rapid monitoring of plant growth regulators in bean sprouts via automated on-line polymeric monolith solid-phase extraction coupled with liquid chromatography tandem mass spectrometry.
Nian, Qixun; Ai, Lianfeng; Li, Dongmei; Chen, Xuelei; Zhang, Lei; Wang, Manman; Wang, Xuesheng.
Afiliação
  • Nian Q; School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
  • Ai L; Hebei Entry-Exit Inspection and Quarantine Bureau, No. 318, Heping West Road, Shijiazhuang, 050000, Hebei, China.
  • Li D; School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
  • Chen X; School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
  • Zhang L; School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
  • Wang M; School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China. mmwangheuu@126.com.
  • Wang X; School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
Anal Bioanal Chem ; 410(27): 7239-7247, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30151683
An automated on-line solid-phase extraction (SPE) following liquid chromatography tandem mass spectrometry was established for the fast determination of plant growth regulator residues in soybean sprout and mung bean sprout. The crude extracted specimens were directly purified on a poly (2-(dimethylamino) ethyl methacrylate-co-ethylene dimethacrylate) monolithic column which was well-defined as the on-line SPE adsorbent. Under the optimized conditions, the developed method gave the linear range of 0.3-50 ng/mL for gibberellin and 2,4-dichlorophenoxyacetic acid, 0.2-50 ng/mL for 4-chlorophenoxyacetic acid, and 0.5-50 ng/mL for 1-naphthaleneacetic acid (r ≥ 0.998). The detection limits (S/N = 3) ranged from 1.0 to 2.5 µg/kg and the recoveries for spiked soybean sprout samples were in the range of 75.0-93.3%. Besides, the total time for one analysis was 16 min. The reusability of the monolith was up to 600 extractions. The proposed process facilitated fully automated SPE and accurate determination in one step with rapidity, simplicity, and reliability. Graphical abstract ᅟ.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reguladores de Crescimento de Plantas / Glycine max / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Vigna Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reguladores de Crescimento de Plantas / Glycine max / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Vigna Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China