Your browser doesn't support javascript.
loading
Cardiac resynchronization therapy and outcomes in patients with left ventricular assist devices: a systematic review and meta-analysis.
Voruganti, Dinesh Chandra; Briasoulis, Alexandros; Chaudhry, Mohsan; Alvarez, Paulino; Cotarlan, Vlad; Bhama, Jay K; Giudici, Michael.
Afiliação
  • Voruganti DC; Department of Internal Medicine, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242, USA. dinesh-voruganti@uiowa.edu.
  • Briasoulis A; Division of Cardiovascular Diseases, University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Chaudhry M; Department of Internal Medicine, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242, USA.
  • Alvarez P; Division of Cardiovascular Diseases, University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Cotarlan V; Division of Cardiovascular Diseases, Section of Heart Failure and Transplant, University of Cincinnati Hospitals, Cincinnati, OH, USA.
  • Bhama JK; Department of Surgery, Division of Cardiothoracic Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Giudici M; Division of Cardiovascular Diseases, University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
Heart Fail Rev ; 24(2): 229-236, 2019 03.
Article em En | MEDLINE | ID: mdl-30259285
ABSTRACT
The impact of cardiac resynchronization therapy (CRT) on clinical outcome in patients with a continuous-flow left ventricular assist device (LVAD) is currently not well understood. We conducted a systematic literature review and meta-analysis with an intention to summarize all published clinical evidence. We searched MEDLINE and EMBASE databases through March 2018 for studies that compared the outcomes in patients with LVAD and CRT. Pooled odds ratios (OR) and 95% confidence intervals (CI) were calculated using a random-effects model, inverse variance method. The between-study heterogeneity was assessed using the Q statistic and I2. A total of seven studies that included 1157 (575 CRT; 582 non-CRT) patients were identified. Our meta-analysis did not demonstrate a significant difference in the risk of mortality (pooled OR = 1.21, 95% CI 0.90-1.63, P = 0.21), ventricular arrhythmia incidence (pooled OR = 1.36, 95% CI 0.99-1.86, P = 0.06), hospitalization (pooled OR = 1.36, 95% CI 0.59-3.14, P = 0.48), or implantable cardioverter defibrillator therapies (pooled OR = 1.08, 95% CI 0.51-2.30, P = 0.84) among the CRT group compared with the non-CRT group. There was high heterogeneity with an I2 of 75% for ICD therapies. Among LVAD patients, CRT combined did not significantly affect mortality, re-hospitalization, ventricular arrhythmia incidence, and ICD therapies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Coração Auxiliar / Terapia de Ressincronização Cardíaca / Ventrículos do Coração Tipo de estudo: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Fail Rev Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Coração Auxiliar / Terapia de Ressincronização Cardíaca / Ventrículos do Coração Tipo de estudo: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Fail Rev Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos