Simultaneous Determination of Uranium and Depleted Uranium Isotopic Ratio Using Inductively Coupled Mass Spectrometry.
Velez-Quinones, Maria A; Xu, Hanna; Vo, Nhu; Gaitens, Joanna M; McDiarmid, Melissa A; Lewin-Smith, Michael R; Strathmann, Frederick G.
Afiliação
  • Velez-Quinones MA; Environmental Toxicology Laboratory, The Joint Pathology Center, Silver Spring, Maryland.
  • Xu H; Environmental Toxicology Laboratory, The Joint Pathology Center, Silver Spring, Maryland.
  • Vo N; Environmental Toxicology Laboratory, The Joint Pathology Center, Silver Spring, Maryland.
  • Gaitens JM; Environmental Toxicology Laboratory, The Joint Pathology Center, Silver Spring, Maryland.
  • McDiarmid MA; Division of Occupational and Environmental Medicine, Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland.
  • Lewin-Smith MR; Department of Veterans Affairs, Baltimore VA Medical Center, Baltimore, Maryland.
  • Strathmann FG; Division of Occupational and Environmental Medicine, Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland.
Curr Protoc Toxicol ; 78(1): e59, 2018 11.
Article em En | MEDLINE | ID: mdl-30286284
We have developed and validated a method for the simultaneous quantitative measurement of total uranium (TU) and uranium 235 U/238 U isotopic ratio (UIR) in urine by inductively coupled plasma mass spectrometry (ICP-MS) using a Thermo Scientific iCAP-Q instrument. The performance characteristics of the assay were determined to be in compliance with clinical laboratory standards. The assay was linear in the concentration range of 1.0 to 500.0 ng/liter TU. The method was precise and accurate with limits of detection of 2.5 ng/liter for TU and 9.8 ng/liter for UIR. The accuracy was >93% and the coefficient of variation (% CV) was <5.0% for both TU and UIR. All results were within established guidelines and agreed-upon criteria, and the results fell within the certified range for the reference controls. The method has thus been shown to be effective as a simple, precise, and sensitive analytical technique for testing urine samples. © 2018 by John Wiley & Sons, Inc.