Your browser doesn't support javascript.
loading
Work of breathing during HHHFNC and synchronised NIPPV following extubation.
Charles, Elinor; Hunt, Katie A; Rafferty, Gerrard F; Peacock, Janet L; Greenough, Anne.
Afiliação
  • Charles E; MRC & Asthma UK Centre for Allergic Mechanisms in Asthma, King's College London, NICU, 4th Floor Golden Jubilee Wing, King's College Hospital, Denmark Hill, London, SE5 9RS, UK. Elinor.charles@nhs.net.
  • Hunt KA; Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK. Elinor.charles@nhs.net.
  • Rafferty GF; MRC & Asthma UK Centre for Allergic Mechanisms in Asthma, King's College London, NICU, 4th Floor Golden Jubilee Wing, King's College Hospital, Denmark Hill, London, SE5 9RS, UK. Katie.a.hunt@kcl.ac.uk.
  • Peacock JL; Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK. Katie.a.hunt@kcl.ac.uk.
  • Greenough A; Centre for Human and Aerospace Physiological Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK.
Eur J Pediatr ; 178(1): 105-110, 2019 Jan.
Article em En | MEDLINE | ID: mdl-30374754
Our aim was to compare the work of breathing (WOB) during synchronised nasal intermittent positive pressure ventilation (SNIPPV) and heated humidified high flow nasal cannula (HHHFNC) when used as post-extubation support in preterm infants. A randomised crossover study was undertaken of nine infants with a median gestational age of 27 (range 24-31) weeks and post-natal age of 7 (range 2-50) days. Infants were randomised to either SNIPPV or HHHFNC immediately following extubation. They were studied for 2 h on one mode and then switched to the other modality and studied for a further 2-h period. The work of breathing, assessed by measuring the pressure time product of the diaphragm (PTPdi), and thoracoabdominal asynchrony (TAA) were determined at the end of each 2-h period. The infants' inspired oxygen requirement, oxygen saturation, heart rate and respiratory rate were also recorded. The median PTPdi was lower on SNIPPV than on HHHFNC (232 (range 130-352) versus 365 (range 136-449) cmH2O s/min, p = 0.0077), and there was less thoracoabdominal asynchrony (13.4 (range 8.5-41.6) versus 36.1 (range 4.3-50.4) degrees, p = 0.038).Conclusion: In prematurely born infants, SNIPPV compared to HHHFNC post-extubation reduced the work of breathing and thoracoabdominal asynchrony. What is Known: • The work of breathing and extubation failure are not significantly different in prematurely-born infants supported by HHHFNC or nCPAP. • SNIPPV reduces inspiratory effort and increases tidal volume and carbon dioxide exchange compared to nCPAP in prematurely born infants. What is New: • SNIPPV, as compared to HHHFNC, reduced the work of breathing in prematurely-born infants studied post-extubation. • SNIPPV, as compared to HHHFNC, reduced thoracoabdominal asynchrony in prematurely born infants studied post-extubation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trabalho Respiratório / Ventilação com Pressão Positiva Intermitente / Extubação / Ventilação não Invasiva Tipo de estudo: Clinical_trials Limite: Female / Humans / Male / Newborn Idioma: En Revista: Eur J Pediatr Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trabalho Respiratório / Ventilação com Pressão Positiva Intermitente / Extubação / Ventilação não Invasiva Tipo de estudo: Clinical_trials Limite: Female / Humans / Male / Newborn Idioma: En Revista: Eur J Pediatr Ano de publicação: 2019 Tipo de documento: Article