Your browser doesn't support javascript.
loading
Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator.
Kubkowska, M; Czarnecka, A; Fornal, T; Gruca, M; Jablonski, S; Krawczyk, N; Ryc, L; Burhenn, R; Buttenschön, B; Geiger, B; Grulke, O; Langenberg, A; Marchuk, O; McCarthy, K J; Neuner, U; Nicolai, D; Pablant, N; Schweer, B; Thomsen, H; Wegner, Th; Drews, P; Hollfeld, K-P; Killer, C; Krings, Th; Offermanns, G; Satheeswaran, G; Kunkel, F.
Afiliação
  • Kubkowska M; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Czarnecka A; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Fornal T; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Gruca M; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Jablonski S; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Krawczyk N; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Ryc L; Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland.
  • Burhenn R; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Buttenschön B; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Geiger B; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Grulke O; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Langenberg A; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Marchuk O; Forschungszentrum, 52425 Juelich, Germany.
  • McCarthy KJ; Laboratorio Nacional de Fusion, CIEMAT, Avenida Complutense, Madrid, Spain.
  • Neuner U; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Nicolai D; Forschungszentrum, 52425 Juelich, Germany.
  • Pablant N; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Schweer B; Forschungszentrum, 52425 Juelich, Germany.
  • Thomsen H; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Wegner T; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Drews P; Forschungszentrum, 52425 Juelich, Germany.
  • Hollfeld KP; Forschungszentrum, 52425 Juelich, Germany.
  • Killer C; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
  • Krings T; Forschungszentrum, 52425 Juelich, Germany.
  • Offermanns G; Forschungszentrum, 52425 Juelich, Germany.
  • Satheeswaran G; Forschungszentrum, 52425 Juelich, Germany.
  • Kunkel F; Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany.
Rev Sci Instrum ; 89(10): 10F111, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399723
The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Polônia