Your browser doesn't support javascript.
loading
Clinical Performance of the BioPlex 2200 Syphilis Total & RPR Assay at a Tertiary Medical Center with a High Rate of Syphilis.
Tesfazghi, Merih T; Anderson, Neil W; Gronowski, Ann M; Yarbrough, Melanie L.
Afiliação
  • Tesfazghi MT; Department of Pathology and Immunology, Washington University School of Medicine, Saint Louis, Missouri, USA.
  • Anderson NW; Department of Pathology and Immunology, Washington University School of Medicine, Saint Louis, Missouri, USA.
  • Gronowski AM; Department of Pathology and Immunology, Washington University School of Medicine, Saint Louis, Missouri, USA.
  • Yarbrough ML; Department of Pathology and Immunology, Washington University School of Medicine, Saint Louis, Missouri, USA myarbro@wustl.edu.
J Clin Microbiol ; 57(1)2019 01.
Article em En | MEDLINE | ID: mdl-30429251
ABSTRACT
Manual treponemal and nontreponemal serologic testing has historically been used for the diagnosis of syphilis. This approach is simple and reproducible but labor intensive. Recently, the FDA cleared the fully automated BioPlex 2200 Syphilis Total & RPR assay for the detection of treponemal and nontreponemal antibodies. We evaluated the clinical performance of this assay at a tertiary medical center with a high syphilis prevalence. Prospective consecutively collected (n = 400) and known RPR-positive (n = 100) specimens were compared using predicate manual rapid plasma reagin (RPR) and fluorescent treponemal antibody absorption (FTA) methods and the BioPlex 2200 Syphilis Total & RPR assay. Positive and negative percent agreements (PPA and NPA, respectively) between the assays were calculated. The PPA and NPA between the manual and BioPlex 2200 RPR results for the prospective population were 85% (17/20; 95% confidence interval [CI], 69% to 100%) and 98% (373/380; 95% CI, 97% to 99%), respectively. The PPA for the manual RPR-positive population was 88% (88/100; 95% CI, 82% to 94%). Overall, the manual and BioPlex 2200 RPR titers demonstrated 78% (99/127) concordance within ±1 dilution and 94% (120/127) within ±2 dilutions. An interpretation of the syphilis serologic profile using the traditional algorithm showed a concordance of 99.5% in the prospective population and 85% in the manual RPR-positive cohort. The performance of the BioPlex 2200 Syphilis Total & RPR assay is comparable to those of manual methods. The high NPA of this assay combined with the ability to automate a historically labor-intensive assay is an appealing attribute for syphilis screening in a high-volume laboratory.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Treponema / Sorodiagnóstico da Sífilis / Sífilis / Programas de Rastreamento / Técnicas Imunoenzimáticas Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: J Clin Microbiol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Treponema / Sorodiagnóstico da Sífilis / Sífilis / Programas de Rastreamento / Técnicas Imunoenzimáticas Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: J Clin Microbiol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos