Toward predictive modeling of catheter-based pulmonary valve replacement into native right ventricular outflow tracts.
Catheter Cardiovasc Interv
; 93(3): E143-E152, 2019 02 15.
Article
em En
| MEDLINE
| ID: mdl-30444053
BACKGROUND: Pulmonary insufficiency is a consequence of transannular patch repair in Tetralogy of Fallot (ToF) leading to late morbidity and mortality. Transcatheter native outflow tract pulmonary valve replacement has become a reality. However, predicting a secure, atraumatic implantation of a catheter-based device remains a significant challenge due to the complex and dynamic nature of the right ventricular outflow tract (RVOT). We sought to quantify the differences in compression and volume for actual implants, and those predicted by pre-implant modeling. METHODS: We used custom software to interactively place virtual transcatheter pulmonary valves (TPVs) into RVOT models created from pre-implant and post Harmony valve implant CT scans of 5 ovine surgical models of TOF to quantify and visualize device volume and compression. RESULTS: Virtual device placement visually mimicked actual device placement and allowed for quantification of device volume and radius. On average, simulated proximal and distal device volumes and compression did not vary statistically throughout the cardiac cycle (P = 0.11) but assessment was limited by small sample size. In comparison to actual implants, there was no significant pairwise difference in the proximal third of the device (P > 0.80), but the simulated distal device volume was significantly underestimated relative to actual device implant volume (P = 0.06). CONCLUSIONS: This study demonstrates that pre-implant modeling which assumes a rigid vessel wall may not accurately predict the degree of distal RVOT expansion following actual device placement. We suggest the potential for virtual modeling of TPVR to be a useful adjunct to procedural planning, but further development is needed.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Valva Pulmonar
/
Insuficiência da Valva Pulmonar
/
Tetralogia de Fallot
/
Próteses Valvulares Cardíacas
/
Cateterismo Cardíaco
/
Implante de Prótese de Valva Cardíaca
/
Modelagem Computacional Específica para o Paciente
/
Procedimentos Cirúrgicos Cardíacos
/
Modelos Cardiovasculares
Tipo de estudo:
Etiology_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Animals
/
Humans
Idioma:
En
Revista:
Catheter Cardiovasc Interv
Assunto da revista:
CARDIOLOGIA
Ano de publicação:
2019
Tipo de documento:
Article