Your browser doesn't support javascript.
loading
Advantage of Z-stacking for teleconsultation between the USA and Colombia.
Mosquera-Zamudio, Andres; Hanna, Matthew G; Parra-Medina, Rafael; Piedrahita, Ana C; Rodriguez-Urrego, Paula A; Pantanowitz, Liron.
Afiliação
  • Mosquera-Zamudio A; Department of Pathology, Fundación Universitaria Ciencias de la Salud. Hospital de San José, Bogotá, Colombia.
  • Hanna MG; University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Parra-Medina R; Research Institute, Fundación Universitaria Ciencias de la Salud, Bogotá, Colombia.
  • Piedrahita AC; Department of Pathology, Fundación Universitaria Ciencias de la Salud. Hospital de San José, Bogotá, Colombia.
  • Rodriguez-Urrego PA; Research Institute, Fundación Universitaria Ciencias de la Salud, Bogotá, Colombia.
  • Pantanowitz L; Hospital Universitario Fundación Santa Fe de Bogotá, Bogotá, Colombia.
Diagn Cytopathol ; 47(1): 35-40, 2019 Jan.
Article em En | MEDLINE | ID: mdl-30457226
INTRODUCTION: There is an emerging need for telecytology in Colombia as the demand for cytopathology has increased. However, due to economic and technological constraints telecytology services are limited. Our aim was to evaluate the diagnostic feasibility of using whole slide imaging with and without Z-stacking for telecytology in Colombia, South America. METHODS: Archival glass slides from 17 fine needle aspiration smears were digitized employing whole slide imaging (WSI) (Nanozoomer 2.0 HT, Hamamatsu) in one Z-plane at 40x, and panoramic digital imaging (Panoptiq system, ViewsIQ) combining low-magnification digital maps with embedded 40x Z-stacks of representative regions of interest. Fourteen Colombian pathologists reviewed both sets of digital images. Diagnostic concordance, time to diagnosis, image quality (scale 1-10), usefulness of Z-stacking, and technical difficulties were recorded. RESULTS: Image quality scored by pathologists was on average 8.3 for WSI and 8.7 for panoramic images with Z-stacks (P = .03). However, diagnostic concordance was not impacted by image quality ranking. In the majority of cases (72.4%) pathologists deemed Z-stacking to be diagnostically helpful. Technical issues related to Z-stack video performance constituted only a minor proportion of technical problems reported. Slow downloads and crashing of files while viewing were mostly experienced with larger WSI files. CONCLUSION: This study demonstrated that international telecytology for diagnostic purposes is feasible. Panoramic images had to be acquired manually, but were of suitable diagnostic quality and generated smaller image files associated with fewer technical errors. Z-stacking proved to be useful in the majority of cases and is thus recommended for telecytology.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Telepatologia / Consulta Remota Limite: Humans País/Região como assunto: America do norte / America do sul / Colombia Idioma: En Revista: Diagn Cytopathol Assunto da revista: PATOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Colômbia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Telepatologia / Consulta Remota Limite: Humans País/Região como assunto: America do norte / America do sul / Colombia Idioma: En Revista: Diagn Cytopathol Assunto da revista: PATOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Colômbia