Your browser doesn't support javascript.
loading
Transcatheter Closure of Left Ventricular Apical Pseudoaneurysm with an Amplatzer Vascular Plug.
Negri, Francesco; Cernetti, Carlo; Favero, Luca; Minniti, Giuseppe; De Leo, Alessandro; De Simone, Giovanna; Sinagra, Gianfranco.
Afiliação
  • Negri F; Cardiovascular Department, Cardiomyopathy Center, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy; Postgraduate School in Cardiovascular Diseases, University of Trieste, Italy. Electronic address: francesco_negri@yahoo.it.
  • Cernetti C; Cardiology Department, Ca' Foncello Hospital Azienda N 2 Marca Trevigiana, Treviso, Italy; Head of Cardio-Neuro-Vascular Department Ca' Foncello and San Giacomo Hospital Azienda N 2, Marca Trevigiana, Treviso, Italy.
  • Favero L; Cardiology Department, Ca' Foncello Hospital Azienda N 2 Marca Trevigiana, Treviso, Italy.
  • Minniti G; Cardiosurgery Department, Ca' Foncello Hospital Azienda N 2 Marca Trevigiana, Treviso, Italy.
  • De Leo A; Cardiology Department, Ca' Foncello Hospital Azienda N 2 Marca Trevigiana, Treviso, Italy.
  • De Simone G; Cardiology Department, Ca' Foncello Hospital Azienda N 2 Marca Trevigiana, Treviso, Italy.
  • Sinagra G; Cardiovascular Department, Cardiomyopathy Center, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy; Postgraduate School in Cardiovascular Diseases, University of Trieste, Italy.
Cardiovasc Revasc Med ; 20(11): 1033-1035, 2019 Nov.
Article em En | MEDLINE | ID: mdl-30655010
We report the case of a 66-year-old man, with a history of previous chest radiation therapy admitted to ED for heart failure. The patient was diagnosed with severe aortic stenosis and multivessel coronary disease and underwent surgical aortic valve replacement and coronary artery by pass grafts. Cardiac surgery was complicated by a left ventricular perforation by a venting catheter. The laceration was repaired with a Teflon patch apparently successful. Four months later, a CT scan performed for oncological follow-up demonstrated the complete detachment of the Teflon patch and the formation of a left ventricular pseudoaneurysm. The pseudoaneurysm was effectively treated percutaneously using an Amplatzer Vascular Plug 4.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Cardíaco / Falso Aneurisma / Aneurisma Cardíaco Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Aged / Humans / Male Idioma: En Revista: Cardiovasc Revasc Med Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Cardíaco / Falso Aneurisma / Aneurisma Cardíaco Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Aged / Humans / Male Idioma: En Revista: Cardiovasc Revasc Med Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article