Your browser doesn't support javascript.
loading
External continuous ECG versus loop recording for atrial fibrillation detection in patients who had a stroke.
Sejr, Michala Herskind; May, Ole; Damgaard, Dorte; Sandal, Birgitte Forsom; Nielsen, Jens Cosedis.
Afiliação
  • Sejr MH; Department of Cardiology, Cardiovasculair Research Unit, Regional Hospital West Jutland, Herning, Denmark.
  • May O; Department of Cardiology, Cardiovasculair Research Unit, Regional Hospital West Jutland, Herning, Denmark.
  • Damgaard D; Department of Neurology, Aarhus Universitetshospital, Aarhus, Denmark.
  • Sandal BF; Department of Neurology, Regional Hospital West Jutland, Denmark.
  • Nielsen JC; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark.
Heart ; 105(11): 848-854, 2019 06.
Article em En | MEDLINE | ID: mdl-30898849
ABSTRACT

BACKGROUND:

Detection of atrial fibrillation (AF) in patients who had ischaemic stroke and transient ischaemic attack (IS/TIA) is recommended. We aimed to compare external loop recording (ELR) against simultaneous continuous ECG recording for AF detection in patients who had acute IS/TIA and determine sensitivity, specificity and positive predictive value of AF detection using ELR. We hypothesised ELR to detect 15% fewer patients with AF than continuous ECG recording.

METHODS:

In this prospective cohort study, we included 1412 patients who had acute IS/TIA without prior AF. Monitoring was 48 hours. Primary outcome was AF >30 s. Cardiologist verified AF in continuous ECG was gold standard.

RESULTS:

In continuous ECG, 38 (2.7%) patients had AF. ELR automatically categorised 219/1412 patients (15.5%) with AF, including 32/38 (85%) patients with AF in continuous ECG. After cardiologist adjudication of ELR recordings, AF was diagnosed in 57/219 patients, of which 32 (56%) had AF in continuous ECG. For adjudicated AF detection by ELR, sensitivity was 84%, 95% CI (69% to 94%), specificity was 98%, 95% CI (97% to 99%) and positive predictive value was 56%, 95% CI (42% to 69%).

CONCLUSION:

Automatic AF detection with ELR results in an AF diagnosis in more than five patients without AF for each patient with AF as verified in continuous ECG. For adjudicated AF detection by ELR, sensitivity was confirmed to 84% and specificity 98%. Automatic ELR as investigated in this study may be considered to rule out AF, but it is not suitable as a single monitoring device for AF screening in patients early after stroke. TRIAL REGISTRATION NUMBER NCT02155907.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Telemetria / Isquemia Encefálica / Ataque Isquêmico Transitório / Eletrocardiografia Ambulatorial / Acidente Vascular Cerebral / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Telemetria / Isquemia Encefálica / Ataque Isquêmico Transitório / Eletrocardiografia Ambulatorial / Acidente Vascular Cerebral / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Dinamarca